#methodological rigourDifferent tasks prevent matched architecture benchmarking
The larger 4f system recognizes T among A and U, whereas the compact processor recognizes Y against U. These demonstrations do not establish the stated preservation of recognition performance between architectures.
↳ Figures 3 and 5; Compact meta-optical processor section
#methodological rigourQualitative results leave performance magnitude unresolved
The main text reports images and intensity projections without numerical recognition contrast, edge fidelity, optical efficiency or repeatability measurements. Recognition also uses the letter shapes selected during design rather than a held-out test set.
↳ Figures 2, 3 and 5; Equations 6–8
#positioningBroad interpretation exceeds the limitations discussion
The Discussion does not substantively examine scaling beyond small letter sets, sensitivity to rotation or scale, or chromatic constraints in the compact imaging phase. These omissions limit interpretation of the proposed platform's broader applicability.
↳ Discussion; Figure 5; Equation 9