#reportingThermal mechanism is stated too conclusively
Power-dependent coincidences agree with a calibrated thermal and electromagnetic model, but resonance shifts are not tracked in situ. The AS/S signal also mixes Raman and SFWM contributions, so it is not an independent temperature measurement.
↳ Results and Discussion, Figures 2 and 4; Conclusions
#methodological rigourReplication and measurement uncertainty remain undefined
The central figures do not define independent acquisition or device counts or provide error bars. Uncertainty in the collection calibration is also not propagated into the inferred photon-pair rates.
↳ Figures 2–4 and captions; Methods, Experimental Setup for Coincidence Measurements
#reportingPolarization comparison conflicts with reported results
The Introduction calls poly-Si anisotropic, whereas Results describes the film as isotropic, contradicting the asserted material contrast. The threefold susceptibility estimate is also an effective brightness-derived inference, not an independently isolated intrinsic material property.
↳ Abstract; Introduction, final paragraph; Results and Discussion, final two paragraphs