#methodological rigourCentral sweeps lack quantified repeatability information
Figures 5–6 provide no replicate or capture counts and no dispersion for the central poling comparisons. All measurements concern one packaged device, while Figure 7 uses MSE rather than a conventional dispersion measure.
↳ Sections 4.B–4.D, Figs 5–7
#reportingResilience wording exceeds the tested conditions
The conclusion states that hysteresis has no impact and that the system becomes resilient to perturbations. The evidence establishes behavior under selected square-wave tests, with complete domain saturation inferred rather than directly measured.
↳ Section 5; Section 4.D, Fig. 7
#reportingNumerical and panel references need reconciliation
The 20 V OSNR gain is 0.52 dB in Section 4.C but 0.59 dB in Figure 6(d). Sections 3 and 4.B also differ on 120 versus 125 GBaud DP 32-QAM, and Figure 2's caption conflicts with the text's power-panel references.
↳ Sections 3, 4.B–4.C; Figs 2 and 6