#reportingEfficiency wording exceeds the reported measurements
The abstract calls the conversion efficient, but the reported 1.22 mW is total output across the spectrum. Neither MIR-specific power nor MIR conversion efficiency is quantified.
↳ Abstract; Figure 4c and output-power discussion
#methodological rigourSingle device comparisons limit quantitative confidence
Each condition is represented by a single device, without device-to-device repeatability. Estimated on-chip energy also relies on symmetric coupling inferred from broadband transmission rather than independently measured facet efficiencies.
↳ Figure 4a–c; Results, transmission and coupling discussion
#methodological rigourComb operation remains an untested interpretation
The MIR spectral tooth structure and carrier-envelope offset are not measured. The discussion acknowledges that harmonic overlap can generate interleaved combs, so the spectra do not establish zero-offset comb operation.
↳ Results, final paragraph; Conclusion; reference 42