#methodological rigourPrinted SNR formula leaves BER unresolved
Appendix B divides eye-level separation by a difference of standard deviations rather than the sum required for the Gaussian Q-factor. Agreement between reported SNR and downstream BER values does not establish which formula generated the SNR, and no direct error counting resolves the issue.
↳ Section 3.3; Appendix B, Eqs. (4)–(5); Fig. 8
#reportingFour-channel framing exceeds sequential testing evidence
The title and receiver-level description suggest aggregate four-channel performance, but wavelengths were launched and detected one at a time. Simultaneous optical and electrical crosstalk penalties therefore remain unmeasured.
↳ Title; Sections 3.3–3.4
#reportingHeadline metrics obscure underlying measurement scope
The Abstract describes reference-photodiode measurements as channel-photodiode properties and presents eye-SNR-derived BER as demonstrated performance. Section 3.2 characterizes one reference photodiode, leaving uniformity across the four integrated photodiodes unverified.
↳ Abstract; Sections 3.2–3.3; Conclusion; Appendix B