#positioningNon-volatile circuit framing exceeds the demonstration
The configured mesh circuits were characterized using volatile actuation, while non-volatile measurements used individual test structures. The abstract and conclusion nevertheless describe a realized non-volatile programmable processor.
↳ Abstract; Discussion, operational-mode clarification and conclusion
#reportingSpeed framing mixes modes and exaggerates comparisons
The 80–82 ns response belongs to volatile operation, not the approximately 60 µs non-volatile programming train. The quoted 2–100 µs thermo-optic range implies about 1.4–3.1 orders of magnitude improvement over 82 ns, rather than three to four.
↳ Abstract; Results, Non-volatile PUC, Fig. 2b; Table 1
#methodological rigourRetention drift lacks an independent reference
The 40-minute staircase measurement lacked a passive reference waveguide, so coupling drift cannot be separated definitively from state relaxation. Each level was held for 1.2 minutes, and variability across multiple devices was not reported.
↳ Results, Non-volatile PUC, Fig. 2f–g