#methodological rigourAbstract reverses the measured scaling relationship
The abstract states an inverse dependence on aperture radius, but onset currents rise from approximately 4 to 6.5 mA as aperture diameter increases from 4 to 6 µm. The measurements support approximately direct proportionality instead.
↳ Abstract; Section IV.A; Figure 2
#methodological rigourIndependent device counts are not reported
The number of devices tested per aperture and temperature is unstated, and device-to-device variability is not quantified. This limits confidence in both the reliability comparison and the activation-energy range.
↳ Section III; Section IV.D; Figures 2–5
#reportingIsothermal wording exceeds demonstrated temperature matching
The abstract describes the same maintained internal temperature, while Figure 4 gives estimated temperatures of 134, 127 and 126 °C. Those estimates extrapolate beyond the 20–70 °C calibration range, making the comparison suggestive rather than an exact isothermal demonstration.
↳ Abstract; Sections IV.B–C; Figure 4