#methodological rigourOpen-loop simulation cannot establish laser stability
The numerical model injects a prescribed pulse and measures backward power without simulating the laser cavity's response. It supports differential attenuation, not the claimed confirmation of stable pulsing at the highest booster currents.
↳ Numerical Simulation Results, Fig. 6, Table I, and concluding paragraph
#methodological rigourOptimized comparisons leave performance uncertainty unresolved
Figure 5 selects the best booster current and, for custom boosters, absorber bias separately for each case. Eight PICs from one fabrication run and a single representative time-domain pulse measurement leave uncertainty about reproducibility and pulse properties across operating conditions.
↳ Experimental Setup, Fig. 1(d); Experimental Results, Fig. 5
#reportingBroad applicability and pulsed-only wording overreach
Only one ring-laser architecture and a particular feedback arrangement are tested, despite the general-purpose applicability claim. RF and optical spectra support pulsing but do not independently establish that the entire 2.4 mW output excludes a continuous-wave contribution.
↳ Experimental Results, discussion after Fig. 5; Summary and Conclusions