#methodological rigourHeadline enhancement lacks reported independent replication
The optical profiles and 48% enhancement comparison do not report independent replicate counts or dispersion. The precision of the enhancement and reproducibility of the phase ranking therefore remain unestablished.
↳ Sections 2.1 and 4.2; Figures 5, 12, and 16
#reportingIonization claims exceed direct experimental measurement
The experiment measures emission, while local ionization and its mechanism are inferred through a simplified 1D model. The Abstract presents ionization enhancement as experimentally achieved despite model omissions and the baseline model–experiment asymmetry.
↳ Abstract; Sections 2.2 and 3.2; Figures 5–6
#reportingField magnitude and combined settings remain unclear
The reported sheath dimensions imply approximately 7.1%, rather than 25%, average-field enhancement under an unchanged-potential approximation. Figure 16 also does not explicitly specify the exact gap and phase used for the combined condition.
↳ Sections 3.2 and 4.2; Figures 10 and 16