#methodological rigourControls do not isolate acoustic origin
No pump-detuning sweep or equivalent acoustic-discrimination test separates a Brillouin response from other three-field nonlinear contributions. Figure 6's claim that the source-dropout result confirms a BDG interaction therefore exceeds what those controls establish.
↳ Experimental Setup; Results, Figs. 6–7
#methodological rigourReflected power calculation requires numerical correction
Equation (9) and its printed inputs give approximately −140.7 dBm at the photodiode, not −149.7 dBm. The subsequent loss budget is also incompletely reconciled, preventing a unique corrected on-chip power estimate.
↳ Results, Eq. (9) and reflected-power calculation
#methodological rigourSpectral characterization stops short of bandwidth
Two probe wavelengths do not establish the reflection-bandwidth profile. The reported 603 Hz heterodyne beat linewidth is not a measurement of that profile, and the treatment of the central interference spike in fitting is unexplained.