#methodological rigourConclusion reverses lens-specific optical result labels
The Conclusion assigns 98.5% overlap and a 5.1 µm spot to the refractive lens, whereas Section 4.3 and Figure 11 assign them to the diffractive lens. The corresponding refractive results are 99.3% and 5.0 µm; the general focusing result survives, but the exact summary assignments do not.
↳ Section 5 versus Section 4.3 and Figure 11
#methodological rigourOptical replication and variability remain unspecified
The number of independent emitters and microlenses behind the final beam-profiling and coupling results is unstated. The uncertainties on the optimal coupling ratios measure variation over time, not reproducibility across devices.
↳ Section 4.3 and Figure 11
#reportingHeadline interpretations exceed the measured quantities
The 0.99 coupling figure is relative to post-lens multimode-fiber collection, not total emitted power. Intensity-profile agreement does not establish complex-field matching, and manufacturer specifications do not provide a paired pre-integration reference for the strain inference.