#methodological rigourHeadline coefficient precision exceeds documented uncertainty support
The coefficients depend on assumed domain populations and material constants, while replicate counts and error-bar definitions are unstated. Propagating the printed e15 uncertainty gives approximately ±3.47 pm/V rather than ±1.5 pm/V, and the Abstract does not identify the quoted coefficients as inferred single-domain values.
↳ Abstract; Results, piezoelectric extraction; SI §§1.2 and 1.5
#reportingPhotoelastic superiority uses unlike coefficient definitions
The extracted peff sets unresolved tensor elements equal and uses PMMA values for the CSAR contribution. Comparing that effective scalar directly with LiNbO3's individual tensor element does not establish a like-for-like threefold material advantage.
↳ Results, photoelastic comparison; SI §§2.2.2–2.2.3; Table S2
#methodological rigourDevice benchmarks depend on incompletely stated conventions
Table S1's index modulation is half the value obtained by inserting the stated 8.4 pm shift directly into Eq. S36, leaving an amplitude convention unresolved. Absorbed-power voltage referencing and the equal-arm modulation approximation further qualify comparisons of the nominal VπL.
↳ Results, Fig. 3; SI §§1.6 and 2.1–2.2; Table S1