#methodological rigourSingle-device measurements leave coupling parameters underdetermined
All six reported lines come from one device, with repeat-sweep and uncertainty procedures incompletely specified. Non-resonant excitation of unresolved dipoles also prevents unique separation of lateral offset, mirror reflectivity, and emitter–waveguide coupling.
↳ Sections II–IV; Table I
#reportingReported visibilities need a reconciled extraction convention
The featured emitter's intensity visibility is 0.48 ± 0.01 in the text but 0.42 in Table I. For QD 2, the printed rate extrema give a normalized contrast of 0.194 rather than the listed 0.15 ± 0.01, with separate-fit extraction left unexplained.
↳ Section III; Table I, QDs 1–2
#reportingSpatial alignment wording exceeds demonstrated phase control
The device adjusts the axial standing-wave phase rather than correcting lateral emitter placement. The conclusion's broader spatial-alignment wording obscures this distinction, even though lateral offsets remain inferred.
↳ Section IV; Figs 2–3