# Magnetic properties and growth kinetics of Co/Gd bilayers with perpendicular magnetic anisotropy

- **DOI:** [10.48550/arxiv.2412.03333](https://doi.org/10.48550/arxiv.2412.03333)
- **Rating:** Sound (3.0 out of 5)
- **Verdict:** Broad magnetic mapping establishes Gd-thickness sensitivity in Co/Gd bilayers, but the printed analytical model contradicts its claimed phase-diagram agreement.
- **Framework version:** v5.13
- **Pipeline version:** v0.4
- **Evaluation date:** 2026-11-25
- **Evaluation page:** https://www.nabu.science/paper/10.48550%2Farxiv.2412.03333

## Key claims

1. TC, and by extension the conditions for PMA and magnetic compensation, are strongly influenced by the thickness of Gd, inducing changes of up to 150 K in TC [in Pt/Co/Gd trilayers].
   - Support: Supported
   - Type: Primary finding
   - Basis: complementary magnetic measurements support thickness sensitivity despite unquantified temperature-extraction uncertainty and sample variability
   - Location: Section I, paragraph 5
2. [The Curie temperature and PMA/compensation conditions of Pt/Co/Gd] are not only impacted by the interface quality, which can be influenced by the sputtering process, but also to a significant extent by finite-size effects in the 4f-material.
   - Support: Tentative
   - Type: Secondary
   - Basis: magnetic measurements and fitted models do not isolate finite-size effects from competing growth and interface changes
   - Location: Abstract; Conclusion
3. the shift in TC in the stack and the expected increased effective exchange due to finite-size effects in the Gd can quantitatively explain the main trends in the phase diagram using parameters from similar experiments
   - Support: Unsupported
   - Type: Secondary
   - Basis: the printed temperature equation reverses the fitted experimental trend rather than reproducing it
   - Location: Section III.B, Fig. 8, Table I
4. Comparing the MOKE signal (Fig. 5a) for the 0.01 mBar sample to the 0.001 mBar sample (orange), we observe that both the transition to the Gd-dominated regime and the transition to the paramagnetic regime are shifted toward lower Gd thicknesses.
   - Support: Supported
   - Type: Secondary
   - Basis: pressure-dependent magnetic transitions are observed without direct structural verification of the accompanying interface changes
   - Location: Section II.D, paragraph 4
5. the trend between the working gas pressure and the magnetostatic response of our Co/Gd systems is clear and suggests that sputter-induced intermixing can play a significant role in these kinds of system
   - Support: Tentative
   - Type: Secondary
   - Basis: intermixing is inferred without direct interface measurements or exclusion of other pressure-dependent growth changes
   - Location: Section II.D, Fig. 5; Fig. 7

## Strengths

- **Broad thickness mapping establishes magnetic trends** Double-wedge measurements cover a wide Co/Gd thickness range and connect magnetic phase boundaries with independent SQUID temperature sweeps. The resulting thickness dependence extends beyond the immediate interface regime.
  - Dimension: contribution
  - Location: Sections II.B–C; Figs. 1–4 and 9
- **Complementary magnetic measurements and growth controls** Polar and longitudinal MOKE distinguish magnetic transitions, while the pressure series is supported by capping-layer comparisons and in-situ oxidation measurements.
  - Dimension: methodological rigour
  - Location: Sections II.B–D; Figs. 2–5; Appendix B, Fig. 10
- **Discussion engages opposing findings and model limits** The discussion addresses the opposite Curie-temperature trend reported for Pt/Co/Pt and explains why the layered Weiss model misses the large-Gd-thickness boundary.
  - Dimension: positioning
  - Location: Sections II.C and III.A–B

## Limitations

- **Printed model reverses its experimental input** Eqs. (8)–(9) and Table I yield approximately 188 K and 404 K at 2.59 nm and 10 nm Gd for 0.7 nm Co, reversing the fitted temperature trend. Moreover, entering the measured trend as a model input cannot independently establish its physical origin.
  - Dimension: methodological rigour
  - Location: Section III.B; Eqs. (8)–(9); Table I; Fig. 8
- **Final mechanism attribution exceeds acknowledged uncertainty** Section II.C states that the temperature reduction is not yet understood, but the Abstract and Conclusion attribute it to finite-size effects. The measurements and fitted models do not uniquely isolate that mechanism.
  - Dimension: positioning
  - Location: Abstract; Sections II.C, III.B and IV
- **Conflicting parameters and unquantified temperature extraction** The text and Table I disagree on c2 (9 versus 20 nm) and λ0 (0.3 versus 0.6 nm), while the SQUID series is labeled with 0.8 versus 0.7 nm Co. The 500 mT temperature sweeps also lack a stated extraction criterion and quantified sample-to-sample uncertainty.
  - Dimension: methodological rigour
  - Location: Section II.C; Fig. 4 and caption; Section III.B; Table I

## Reliability checks

Caveats (4 of 4 checks).

- **Results check:** Noted
  - "observe that the earlier phase diagram (Fig.1d) reproduces quite well." (Section III.B, discussion of Fig. 8) vs "TC = a0tCo −(TC(tGd) −TC(0))) ," (Section III.B, Eq. (9)). Eq. (8) and Table I give approximately 307 K, 412 K and 196 K at 0, 2.59 and 10 nm Gd, respectively, but Eq. (9) at 0.7 nm Co gives approximately 188 K and 404 K at 2.59 and 10 nm, reversing the fitted changes. The claim is not supported by the paper's own data.
  - "but we adjust c2 = 9 nm such that the scaling law matches" (Section III.B, text vs Table I (c2)) vs "γ 2.8 - c2 20 nm Jexχ -1" (Table I, analytical-model parameters). The text specifies c2 = 9 nm while Table I specifies 20 nm for the calculation of Fig. 8. The effect on the result is unclear.
  - "We take λ0 = 0.3 nm after the results of Lim and Omelchenko" (Section III.B, decay-length discussion) vs "Jexχ -1 - λ0 0.6 nm β 0.4" (Table I, decay-length parameter). The text specifies λ0 = 0.3 nm while Table I specifies 0.6 nm for the calculation of Fig. 8. The effect on the result is unclear.
  - "Ta(4)/Pt(4)/Co(0.8)/Gd(tGd)/TaN(4)/- Pt(2)" (Section II.C, SQUID sample description) vs "Ta(4)/Pt(4)/Co(0.7)/Gd(x)/TaN(4)/Pt(2) samples" (Fig. 4 legend). Section II.C assigns 0.8 nm Co to the SQUID series while Fig. 4 assigns 0.7 nm, without reversing the reported trend across Gd thicknesses. The result itself is unaffected.
- **Reporting and transparency:** Clean. No adverse research-conduct or transparency finding is established in the supplied text. Reporting and cross-reference defects are addressed under Internal Coherence and Clarity.
  - Data availability: not stated · Code availability: not stated
- **Reference integrity:** Clean
  - 89 references in manuscript
  - 88 of 88 checkable references found in an index
  - 1 have no canonical index record — counted, but not index-checkable
  - 1 mistyped DOI matched to the cited work by its details
  - 11 references confirmed by manual review
  - References not verified automatically are resolved manually within 24 hours.

## Post-publication record

- **Status:** Clean
- **Summary:** No retraction or expression of concern found in Crossref (includes Retraction Watch).
- **Last checked:** 2026-11-25