#methodological rigourCutback uncertainty and summary range remain unclear
The cutback measurements vary length and die location together without reporting fit uncertainty or replication detail. The Introduction and Conclusions give 0.12~0.15 dB/cm, versus 0.13~0.15 dB/cm in the Abstract and results.
↳ Abstract; Sections 1, 3 and 6; Figure 2d; Table A1
#methodological rigourSmall stitch signals challenge extraction precision
Table A1's stitch-loss spreads cross zero, and the confidence-interval construction does not establish how within-die pairing and wafer variation were handled. The imposed-offset comparison uses one offset and one reference wafer per thickness, limiting isolated causal attribution.
↳ Sections 4–5; Figures 6–8; Table A1; Appendix A.3
#positioningPrior stitch-loss benchmarking remains quantitatively incomplete
The platform comparison explains confinement and fabrication trade-offs but does not directly benchmark measured stitch loss against the closest cited demonstrations. This limits how precisely the advance over prior stitching can be judged.
↳ Section 2, Table 1; Sections 3–4