#reportingMinimum feature claim conflicts with dimensions
The abstract specifies features larger than 200 nm, but Section 3.1 reports nominal 200-nm features. Table 1 separately lists 205 nm, leaving the numerical fabrication specification inconsistent across the paper.
↳ Abstract; Section 3.1; Table 1
#methodological rigourNumerical validation details remain insufficiently reported
Mesh convergence, boundary settings, and stochastic optimization stability are not established in the reported account. These omissions matter particularly for the nanometer-scale tolerance sweeps, while inconsistent grating dimensions complicate reproduction.
↳ Sections 3.1–3.2; Figure 6
#reportingHeadline framing exceeds the demonstrated comparison
The abstract leaves the simulation-only basis of efficiency and tolerance implicit. The conclusion's favorable performance-balance claim also lacks a like-for-like comparison, since Table 1 combines different coupling geometries and fabrication constraints.
↳ Abstract; Section 4; Table 1