#methodological rigourIndependent replication and precision remain undefined
The central comparisons do not define specimen counts or independently prepared mixes sufficiently to assess precision. Repeating density measurements six times does not resolve replication for compressive strength.
↳ §3.2.2; §§4.1–4.4, Figs. 3–9
#reportingMechanistic certainty exceeds the direct measurements
Similar TGA water-loss profiles do not directly establish identical microporosity or platelet organization. The assertion that only entrapped-air porosity affects final strength excludes alternatives that the comparisons do not independently test.
↳ Abstract; §4.5, Figs. 10–13; §5 Conclusion
#impact potentialPractical transfer beyond kaolin remains untested
The study uses one kaolin–sand system at laboratory-prism scale. Other mineralogies, water sensitivity, durability, and field-scale performance remain outside the demonstrated application scope.