- **Rating:** Limited (2.9 out of 5)
- **Verdict:** Three GBM spheroid protocols provide practical growth and drug-response benchmarks, but their uniformity and cellular-heterogeneity claims exceed the measurements.
- **Framework version:** v5.10
- **Pipeline version:** v0.4
- **Evaluation date:** 2026-10-23
- **Evaluation page:** https://www.nabu.science/paper/10.1371%2Fjournal.pone.0276248

## Key claims

1. The expected results from these protocols confirmed the ability of all these methods to create uniform tumourspheres.
   - Support: Tentative
   - Type: Primary finding
   - Basis: mean diameter measurements do not provide an operational uniformity criterion or a spheroid-level dispersion assessment
   - Location: Abstract, final sentence
2. These results proved that these protocols have the ability to develop 3D tumourspheres and the presence of heterogeneous cellular subpopulations such as actively proliferating, quiescent, hypoxic, and necrotic cells
   - Support: Tentative
   - Type: Secondary
   - Basis: formation and diameter measurements do not identify proliferation, quiescence, hypoxia, or necrosis
   - Location: Expected Results and Discussion, after Fig 2 paragraphs
3. According to the results, 5x106 cells/well initial seeding density was the most suitable seeding density for the scaffold based method
   - Support: Tentative
   - Type: Secondary
   - Basis: the stated inoculum is tenfold above the Methods protocol, and optimisation relies on an unvalidated metabolic-to-diameter health proxy
   - Location: Expected Results and Discussion, scaffold-based method
4. U-87 MG has the highest TMZ sensitivity, while U-251 MG tumourspheres showed highest cell viability with TMZ treatment
   - Support: Supported
   - Type: Secondary
   - Basis: two viability assays support the ordering within these cell-line spheroids, without external or in vivo validation
   - Location: Expected Results and Discussion, TMZ paragraph (Fig 6)
5. 10000 cells/ml initial seeding density was the most suitable seeding density for low attachment plate method
   - Support: Tentative
   - Type: Secondary
   - Basis: multiple densities are statistically indistinguishable and suitability depends on an unvalidated diameter-normalised metabolic readout
   - Location: Expected Results and Discussion, low-attachment results

## Strengths

- **Integrated GBM culture and optimisation reference** Three culture formats and three cell lines are accompanied by growth and seeding-density observations, providing practical information beyond formation images alone.
  - Dimension: contribution
  - Location: Materials and Methods; Expected Results and Discussion, Figs 2–5
- **Two assays corroborate relative TMZ sensitivity** Alamar Blue and CellTiter-Glo 3D yield the same cell-line sensitivity ordering. This supports the condition-specific drug-response comparison despite differences in assay chemistry.
  - Dimension: methodological rigour
  - Location: Temozolomide Induced Glioma Cytotoxicity; Expected Results and Discussion, Fig 6
- **Deposited protocols support further model development** Named protocols.io deposits provide persistent procedural references, while the discussion identifies BBB, immune, vascular, and co-culture extensions.
  - Dimension: application pathway
  - Location: Materials and Methods, S1–S3 deposits; Expected Results and Discussion, final paragraphs

## Limitations

- **Scaffold recommendation overstates inoculum ten times** Methods seed 100 μL at 5 × 10^6 cells/ml, delivering 5 × 10^5 cells/well. The Results recommendation instead states 5x106 cells/well and requires correction before reproduction.
  - Dimension: methodological rigour
  - Location: Scaffold Based Method; Expected Results and Discussion, scaffold recommendation
- **Uniformity and cellular states remain unmeasured** Diameter and metabolic measurements do not directly establish spheroid uniformity or proliferating, quiescent, hypoxic, and necrotic subpopulations. The abstract and discussion present those properties as demonstrated.
  - Dimension: reporting
  - Location: Abstract; Expected Results and Discussion, paragraph following Fig 2
- **Inferential unit and health interpretation unclear** The text does not identify whether ANOVAs used individual spheroids or experiment-level summaries. Its fluorescence-to-diameter ratio is also not validated as a measure of spheroid health.
  - Dimension: methodological rigour
  - Location: Growth Analysis; Spheroid Cells Health Analysis; Statistical Analysis

## Reliability checks

Concerns (4 of 4 checks).

- **Results check:** Concern
  - 5x106 cells/well initial seeding density was the most suitable seeding density for the scaffold based method: "100 μL was seeded from a cell suspension with a cell density of 5000k cells/ml." (SCAFFOLD BASED METHOD) vs "5x106 cells/well initial seeding density was the most suitable seeding density for the scaffold based method" (EXPECTED RESULTS AND DISCUSSION, scaffold-based method). Multiplying the stated suspension concentration, 5 × 10^6 cells/ml, by the stated 0.1 ml seeding volume gives 5 × 10^5 cells/well, tenfold below the recommendation. → Changes the size materially
  - Minor reporting notes (1):
    - Descriptive: "One-way ANOVA demonstrated that there was a significant difference in tumoursphere diameter between each initial seeding densities as shown in Fig 3D." (EXPECTED RESULTS AND DISCUSSION, low-attachment seeding-density analysis) vs "However, there was no significant difference between diameters in 10 000, 15 000, and 20 000 cells/ml seeding densities." (EXPECTED RESULTS AND DISCUSSION, low-attachment seeding-density analysis). The assertion of differences between each density conflicts with the immediately stated absence of differences among three densities. → Conclusion holds
- **Reporting and transparency:** Clean. Ethics approval, cell-line sourcing, and mycoplasma testing are declared. No supported reporting or transparency concern is established by the supplied reviews.
  - Ethics approval: declared
- **Reference integrity:** Clean
  - 34 references in manuscript
  - 34 of 34 checkable references found in an index
  - References not verified automatically are resolved manually within 24 hours.

## Post-publication record

- **Status:** Clean
- **Summary:** No retraction or expression of concern found in Crossref (includes Retraction Watch).