# Demonstration of a squeezed light source on thin-film lithium niobate with modal phase matching

- **DOI:** [10.1364/opticaq.562545](https://doi.org/10.1364/opticaq.562545)
- **Rating:** Sound (3.4 out of 5)
- **Verdict:** Modal phase matching delivers measured squeezing in thin-film lithium niobate without periodic poling, but unquantified measurement uncertainty limits confidence in its performance.
- **Framework version:** v5.13
- **Pipeline version:** v0.4
- **Evaluation date:** 2026-11-25
- **Evaluation page:** https://www.nabu.science/paper/10.1364%2Fopticaq.562545

## Key claims

1. we demonstrate a squeezed light source on an integrated TFLN platform, achieving a measured shot noise reduction of 0.46 dB (1.5 dB on-chip) using modal phase matching and grating couplers with an efficiency of up to −2.2 dB.
   - Support: Supported
   - Type: Primary finding
   - Basis: single-device homodyne measurements support off-chip squeezing with the on-chip value dependent on loss assumptions
   - Location: Abstract
2. The achieved squeezing is comparable to what has been observed using more complex circuitry based on periodic poling.
   - Support: Supported
   - Type: Secondary
   - Basis: single-device performance matches the cited measured TFLN benchmark rather than the larger squeezing reported on other periodically poled platforms
   - Location: Abstract; Section 5
3. The simpler design allows for compact, efficient, and reproducible sources of squeezed light.
   - Support: Tentative
   - Type: Secondary
   - Basis: a single unstable device without yield or multi-device measurements cannot establish reproducibility
   - Location: Abstract
4. With 10 mW of on-chip power, the centre of the 1550 nm resonance exhibited an amplification factor of 3.15 and a deamplification factor of 0.5, taken as the highest and lowest value of the ripples.
   - Support: Supported
   - Type: Secondary
   - Basis: the seeded gain scan supports amplification and deamplification without quantified measurement precision or repeatability
   - Location: Section 3, paragraph 3

## Strengths

- **Alternative architecture reaches established TFLN squeezing** Modal phase matching produces a measured 0.46 dB shot-noise reduction without periodic poling, approximately matching the prior measured TFLN benchmark cited in the introduction.
  - Dimension: contribution
  - Location: Sections 1–2 and 4; Figure 6b
- **Complementary measurements support the squeezing demonstration** Seeded parametric gain complements shot-noise-referenced squeezing and anti-squeezing measurements. Pump-power and frequency scans further characterize the observed operation.
  - Dimension: methodological rigour
  - Location: Sections 3–4; Figures 5–6
- **Operating limits connect to concrete mitigations** The discussion traces coupling loss, photorefraction and double-resonance constraints to engineering changes, including improved couplers, temperature or material changes, and integrated tuning.
  - Dimension: positioning
  - Location: Section 5

## Limitations

- **Measurement precision and repeatability remain unquantified** Power and frequency data points come from individual phase scans averaged around extrema, without error bars or independent repeat statistics. This limits precision assessment for the small measured noise reduction.
  - Dimension: methodological rigour
  - Location: Section 4; Figures 6c–6d
- **Operating instability complicates fitted performance estimates** The gain-derived threshold is about 50 mW, compared with about 200 mW from the squeezing fit. Individually retuned double resonance and coupling variation limit the comparability of these operating conditions.
  - Dimension: methodological rigour
  - Location: Sections 3–4; Figures 5–6
- **Reproducibility language exceeds the demonstrated evidence** The abstract asserts efficient and reproducible sources, but only one device is demonstrated, with coupling damage and sparse individually tuned operating points. No device-to-device reproducibility evidence supports that assertion.
  - Dimension: reporting
  - Location: Abstract; Section 4

## Reliability checks

Caveats (3 of 4 checks).

- **Results check:** Noted
  - "we obtained a total efficiency η = 0.20" (Section 4, power-dependence fit paragraph) vs "total efficiency η = 0.23, and cavity bandwidth" (Section 4, frequency-dependence fit paragraph). Compare the separately reported efficiencies of 0.20, 0.23 and approximately 0.24 with the printed component product, 0.85 × 0.98 × 0.45 × 0.55 = 0.2061675. The result itself is unaffected.
  - "an amplification factor of 3.15 and a deamplification factor of 0.5" (Section 3, paragraph 3) vs "This configuration provided a gain coefficient of 3.16, allowing us to measure light squeezed -0.46 dB below shot noise." (Section 5, paragraph 1). The gain summary differs from the measurement description by 3.16 − 3.15 = 0.01. The result itself is unaffected.
- **Reporting and transparency:** Clean. Conflicts of interest are disclosed and a Figshare link is provided for squeezing measurements. No grounded research-conduct finding is retained.
  - Conflict of interest: declared · Data availability: declared
- **Reference integrity:** Noted. 17 of 27 checkable references verified
  - 27 references in manuscript
  - 9 references confirmed by manual review
  - Could not be verified automatically — queued for manual review:
    - F. Lenzini, J. Janousek, O. Thearle, et al., Sci. Adv. 4 (2018). (Crossref bibliographic: only 3/5 fields agree (journal+year+author); volume+page agreement required — left unresolved)
    - T. Kashiwazaki, T. Yamashima, N. Takanashi, et al., Appl. Phys. Lett. 119 (2021). (Crossref bibliographic: only 3/5 fields agree (journal+year+author); volume+page agreement required — left unresolved)
    - T. Kashiwazaki, T. Yamashima, K. Enbutsu, et al., Appl. Phys. Lett. 122 (2023). (Crossref bibliographic search unavailable (search could not be performed) — no conclusion drawn about this reference)
    - Y. Zhang, M. Menotti, K. Tan, et al., Nat. Commun. 12 (2021). (Crossref bibliographic search unavailable (search could not be performed) — no conclusion drawn about this reference)
    - H. S. Stokowski, T. P. McKenna, T. Park, et al., Nat. Commun. 14 (2023). (Crossref bibliographic: only 3/5 fields agree (journal+year+author); volume+page agreement required — left unresolved)
    - T. Park, H. Stokowski, V. Ansari, et al., Sci. Adv. 10, eadl1814 (2024). (Crossref bibliographic: only 3/5 fields agree (journal+year+author); volume+page agreement required — left unresolved)
    - L.-H. Hong, B.-Q. Chen, C.-Y. Hu, and Z.-Y. Li, Phys. Rev. A 98 (2018). (Crossref bibliographic: only 3/5 fields agree (journal+year+author); volume+page agreement required — left unresolved)
    - R. Luo, Y. He, H. Liang, et al., Phys. Rev. Appl. 11 (2019). (Crossref bibliographic search unavailable (search could not be performed) — no conclusion drawn about this reference)
    - J. Lu, J. B. Surya, X. Liu, et al., arXiv: Opt. (2019). (Crossref bibliographic search unavailable (search could not be performed) — no conclusion drawn about this reference)
    - E. Lomonte, M. Stappers, L. Krämer, et al., Sci. Reports 14 (2024). (Crossref bibliographic: only 3/5 fields agree (journal+year+author); volume+page agreement required — left unresolved)
  - References not verified automatically are resolved manually within 24 hours.

## Post-publication record

- **Status:** Not checked
- **Summary:** Post-publication record check unavailable at this time.
- **Last checked:** 2026-11-25