Demonstration of temperature monitoring of the curing process in resin transfer moulding using integrated phase-shifted Bragg grating sensors

Syriopoulos et al.Syriopoulos, Kyriazi, Poulopoulos et al.·2024·Optics Continuum·10.1364/optcon.522327 ↗

Primary claim

The embedded phase-shifted Bragg grating sensors exhibit high sensitivity (75 pm/°C) and linearity (R2=0.995), operating up to 120 °C, allowing precise temperature measurements throughout the curing cycle.

Tentative · single-probe testing with calibration only through 100 °C and no co-located curing reference
In brief

An integrated photonic probe tracks an epoxy-curing cycle to 120 °C, but non-co-located reference measurements leave its claimed accuracy unvalidated.

ReliabilityCaveats4 of 4 checks completeRead the 2 entries ↓
Fragile — the claim's weakest requirement is that the effect is as large as stated. Experimental. Every point below is traceable to a quoted passage, but this forecast has not yet been validated against known replication outcomes.
Abstract

Composite materials have increased in use across multiple industries due to their low weight, thermal stability and design flexibility. As applications grow, the importance of accurate process-monitoring techniques grows, with various research teams investigating a variety of in situ cure-monitoring sensors. Photonic integrated circuits (PICs) can be a feasible solution in tracking curing cycles due to their resistance to harsh conditions and ease of integration into the production tool. This paper demonstrates the integration and performance evaluation of an embedded phase-shifted Bragg grating solution, instead of commonly used fiber sensors, based on 220 nm height silicon-on-insulator platform for in-situ monitoring of the RTM-6 resin curing process in a composite tool. The embedded optical sensor presents high sensitivity (75 pm/°C) and linearity (R 2 =0.995) up to 120 °C, enabling precise temperature measurements throughout the curing cycle. The experimental results show consistency with previously reported simulations, throughout the calibration, dry run characterization and the curing process, up to 120 °C, allowing for accurate monitoring of the curing process.

Key Claims

Primary finding · Tentative

The embedded phase-shifted Bragg grating sensors exhibit high sensitivity (75 pm/°C) and linearity (R2=0.995), operating up to 120 °C, allowing precise temperature measurements throughout the curing cycle.

Fragile — the claim's weakest requirement is that the effect is as large as stated. Experimental. Every point below is traceable to a quoted passage, but this forecast has not yet been validated against known replication outcomes.

single-probe testing with calibration only through 100 °C and no co-located curing reference

Conclusions
Quote verified
Secondary · Tentative

The experimental results show consistency with previously reported simulations, throughout the calibration, dry run characterization and the curing process, up to 120 °C, allowing for accurate monitoring of the curing process.

single-probe comparison with measured sensitivity below simulation and no independent validation of interface accuracy

Abstract
Quote verified
Secondary · Tentative

The optical sensors went through calibration, dry run characterization, and curing process measurements, with the small variations in measurement caused by the local temperature profile in the tool-resin interface.

differently located sensors cannot identify the cause of their measurement differences

Conclusions
Quote verified

Derived from the full evaluation — not a separate score.

Strengths · Limitations

Strengths

#contribution

Photonic probe tested during actual curing

A packaged silicon-photonic sensor records reflection spectra during resin infusion and subsequent heating to 120 °C. This extends the earlier dry-run work to an operating composite tool.

↳ Introduction; Section 3, Figs. 11–13

#methodological rigour

Calibration supports a consistent temperature response

The dry-run calibration is referenced to thermocouples through 100 °C. Reported wavelength shifts of 1.875 nm over 25 °C and 4.125 nm over 55 °C both match the stated 75 pm/°C sensitivity.

↳ Section 3, first paragraph; Figs. 8–9

#positioning

Probe failure and spectral differences disclosed

The results report loss of the second probe's signal above its 30–40 °C test range and describe the broader-than-simulated reflection dip. These disclosures expose relevant packaging and fabrication constraints.

↳ Section 3, spectral-bandwidth discussion and Fig. 10

Limitations

#methodological rigour

Reference placement prevents independent accuracy validation

Thermocouples near the heaters and an optical sensor at the tool edge show a 1–5% difference. That comparison cannot separate sensor error from a real thermal gradient or establish location as the cause of the difference.

↳ Methods §2.3, Fig. 7; Section 3, Fig. 12

#positioning

Single surviving probe limits operating conclusions

Only one probe is followed through a reported curing cycle after the second loses signal during dry testing. Repeatability, hysteresis and drift are not established, and the conclusion does not trace the disclosed probe failure into the scope of its precision claim.

↳ Section 3, Figs. 10–13; Conclusions

#reporting

Headline precision exceeds the reported validation

The headline attaches R2=0.995 to operation through 120 °C, although dry calibration stops at 100 °C and the curing-stage fit is R2=0.988. The Abstract also names RTM-6 while Methods identifies Epikote RIMR 035c/Epikure RIMH 037, leaving the tested material uncertain.

↳ Abstract; Methods §2.3; Section 3, Fig. 13; Conclusions

Does this match your read? Add your assessment ↓

Nabu Commentary

The experiment advances earlier dry-run work by recording a packaged photonic probe during resin infusion and heating to 120 °C. Its calibration and wavelength-shift arithmetic support temperature tracking, but the differently located thermocouples do not independently validate accuracy at the tool–resin interface or establish why the readings differ. One surviving probe and one reported curing cycle limit conclusions about repeatability and operating reliability. The headline precision claim, the distinction between dry and curing-stage linearity, and conflicting resin names make the conclusions more definite than the experimental account warrants.

Evaluate another paper

Free · About 5 minutes · Research preview

Author Note / Field Feedback

Nabu’s assessment, alongside the field’s view.

Are you an author of this paper?

Dimension breakdown

Evidence Score

Out of 5
012345
2.8±0.2

Contribution
3.0

The study extends prior sensor design and dry-run work to an actual resin-infusion and curing sequence. Its contribution remains a bounded engineering demonstration based on one surviving probe and one reported curing cycle.

Introduction, prior-work paragraph; Section 3, Figs. 10–13
Methodological Rigour
2.7

Thermocouple-referenced calibration and internally consistent wavelength shifts support temperature tracking. Non-co-located curing references cannot establish interface accuracy or the cause of the 1–5% difference, while replication and uncertainty estimates are absent.

Methods §2.3; Section 3, Figs. 9–13
Reporting
2.7

The sequence from design to calibration and curing is followable, but headline precision exceeds the reported validation. Conflicting resin identities and an ambiguous installation description also obscure the experimental account.

Abstract; Methods §§2.1 and 2.3; Section 3; Conclusions
Positioning
2.9

The Introduction positions the experiment against electrical sensors, fibre Bragg gratings and the team's earlier dry-run work. The discussion acknowledges probe failure and spectral differences without adequately tracing their consequences into the operating-performance conclusions.

Introduction; Section 3, Fig. 10 and spectral-bandwidth discussion; Conclusions

Reliability

Caveats4 of 4 checks


Results checkNoted
  • "linearity (R2=0.995) up to 120 °C, enabling precise temperature measurements" (Abstract, sensitivity and linearity statement) vs "The sensor was calibrated up to 100°C using the reference thermocouple probe" (Section 3, first paragraph). Compare the headline range with the stated calibration endpoint and the separately reported dry-calibration and curing-stage fits in Section 3 and Fig. 13. The result itself is unaffected.
Reporting and transparencyNoted

The Abstract and Methods identify different resin systems, leaving the demonstrated material uncertain. Conflict-of-interest and data-availability statements are present.

Conflict of interest: declared · Data availability: declared

Reference IntegrityClean

30 of 30 checkable references verified

30 references in manuscript 11 references confirmed by manual review

References not verified automatically are resolved manually within 24 hours.

Post-Publication RecordClean

No retraction or expression of concern found in Crossref (includes Retraction Watch).

Last checked: 25 Nov 2026

Sources: Crossref (incl. Retraction Watch) ✓

Impact Profile

Impact areaProducts and technology · SDG 9
Type of advanceEmpirical
Route to useNamed
AdvanceExtends
CitationsFWCI 0.3
Policy · patentNot yet traced
ReachedNot reachedNot assessable or unverified
ReadinessPiloted
Foundational
Controlled
Piloted
Validated
Implementable
FoundationalImplementable

The sensor is shown working once as a proof of concept in a single composite tool during one curing cycle, validated against thermocouples, but not confirmed across independent settings or repeated production runs.

From the paper
“making it a promising solution for measuring accurate temperature in advanced composite manufacturing processes such as resin transfer molding (RTM)”

The conclusion names the setting that would use these findings, composite manufacturing processes such as RTM, and the purpose, accurate in-situ temperature measurement during curing.

Pathway

Composite part manufacturers in aerospace and automotive industries would embed these PIC temperature sensors in RTM tools for real-time cure monitoring and quality control.

Barrier

The sensor has only been demonstrated in one tool and one curing cycle, so durability, repeatability over multiple production cycles and cost-effective industrial integration remain unproven.

Evaluated 25 Nov 2026 · GBD 2023 · glm_v1_3_3 · impact_profile_v1_3_3

Report an issue →

AI-generated, human-governed. Something look off? Contact us to request a review.

Keep reading

Related evaluations

Other papers Nabu has evaluated blind, starting with the same field.

  1. Densely integrated low polarization dependent 8 × 8 optical switch for optical network applications

    2026 · Electrical engineering, electronic engineering, information engineering

    Primary claim

    Multiple measured paths show promising results: gain over 20 dB, PDG under 3 dB, and high OSNR over 40 dB across the full C-band.

    Tentative
    Evidence Score
    2.8±0.1
    Reliability
    Caveats
  2. A Comparison of Plasmonic Modulator Structures in the O- and C-Band for the 400G/Lane IM/DD Era

    2026 · Electrical engineering, electronic engineering, information engineering

    Primary claim

    All four modulators offer a compact footprint, net-data rates above 400 Gbit/s, and an electro-optic bandwidth above 100 GHz.

    Supported
    Evidence Score
    3.1±0.1
    Reliability
    Caveats
  3. Waveguide Geometry–Driven Trade‐Offs in Resonant Cavity Sensor Performance

    2026 · Physical sciences

    Primary claim

    Despite its lowest sensitivity, the ridge resonator delivers the best performance (Q = 3.5 × 10^5 , LOD = 4.2 × 10− 8 RIU) through superior stability.

    Tentative
    Evidence Score
    2.9±0.1
    Reliability
    Concerns

How the rubric works →