# Opto-electronic simulation of silicon waveguide integrated single photon avalanche diodes

- **DOI:** [10.1364/oe.575965](https://doi.org/10.1364/oe.575965)
- **Rating:** Sound (3.2 out of 5)
- **Verdict:** Coupled optical–electrical simulations identify silicon waveguide SPAD design bottlenecks, but prohibitive dark counts block the predicted high-efficiency operating regime.
- **Framework version:** v5.13
- **Pipeline version:** v0.4
- **Evaluation date:** 2026-11-25
- **Evaluation page:** https://www.nabu.science/paper/10.1364%2Foe.575965

## Key claims

1. Based on imec’s isipp50G technology, simulated devices show the potential of peak photon detection efficiencies (PDE) above 75% at 600 nm, when coupled with a SiN signal waveguide.
   - Support: Tentative
   - Type: Primary finding
   - Basis: unvalidated optical PDE prediction at excess biases where prohibitive dark counts prevent practical operation
   - Location: Abstract
2. In contrast, the etched structure demonstrates superior performance for this application as it is more efficient concentrating most absorption within the core where up to 90.8% of the radiation is absorbed.
   - Support: Well-supported
   - Type: Secondary
   - Basis: direct three-dimensional optical comparison of etched and planar geometries at 600 nm with a fixed oxide gap
   - Location: Section 2.1, Fig. 2
3. Good matching between simulation and experiment is achieved [for dark count rate] when including surface trap effects.
   - Support: Tentative
   - Type: Secondary
   - Basis: single-device agreement on a relative excess-bias scale using a literature-derived trap density despite a 2 V breakdown offset
   - Location: Section 3.2, Fig. 4(d)
4. The current device faces a fundamental challenge in operating above 10 % Vex.
   - Support: Supported
   - Type: Secondary
   - Basis: high-bias noise simulations supported by lower-bias dark-count measurements rather than direct testing across the full predicted operating range
   - Location: Section 3.3, Fig. 5
5. This validates the proposed model as an effective tool to predict device performance.
   - Support: Tentative
   - Type: Secondary
   - Basis: dark-count comparison alone cannot establish predictive accuracy for optical coupling and photon detection efficiency
   - Location: Section 3.2

## Strengths

- **Explicit coupling of optical and electrical models** The workflow combines three-dimensional optical absorption maps, two-dimensional TCAD fields, and analytical avalanche-trigger probabilities. Equations 1–9 make the route to PDE and dark-count estimates explicit.
  - Dimension: methodological rigour
  - Location: Sections 2.1–2.3, Eqs. 1–9
- **Direct comparison isolates the etched geometry advantage** The planar-versus-etched optical simulations identify stronger concentration of absorption in the etched waveguide core at 600 nm. This provides a concrete architectural result separate from the unvalidated detector-efficiency prediction.
  - Dimension: contribution
  - Location: Section 2.1, Fig. 2
- **Dark count limitations guide specific redesign priorities** The discussion connects surface-trap and tunneling noise to restricted operating bias. It then identifies doping asymmetry and separation of the active region from interfaces as design priorities.
  - Dimension: positioning
  - Location: Sections 3.2–3.3; Section 4

## Limitations

- **Headline efficiency omits its unusable bias regime** The Abstract highlights PDE above 75%, but the 76% peak requires high excess bias. Section 3.3 states that dark counts obstruct practical operation above approximately 10% excess bias and block the predicted PDE above 50%.
  - Dimension: reporting
  - Location: Abstract; Section 3.3, Fig. 5
- **Experimental comparison validates only part of performance** The experimental check concerns dark counts from one device, not optical PDE. Simulated and measured breakdown voltages differ by 2 V, and DCR agreement uses a literature-derived surface-trap density on a relative excess-bias scale.
  - Dimension: methodological rigour
  - Location: Section 3.2, Fig. 4(d)
- **Unity carrier collection lacks a quantitative bound** The PDE calculation assumes complete collection from neutral core and rib regions without a quantitative sensitivity bound. This leaves uncertainty in the efficiency prediction, particularly given the substantial interface-trap contribution to the noise model.
  - Dimension: methodological rigour
  - Location: Section 2.3, Eqs. 5–7; Section 3.2

## Reliability checks

Caveats (4 of 4 checks).

- **Results check:** Noted. One reported value does not reconcile, but the key claims do not rest on it.
  - Minor reporting notes (1):
    - "b) 2D contour map of the electric field distribution at the breakdown voltage obtained from TCAD device simulation." (Figure 3 caption, panel b) vs "In Fig. 3(b) and (d), the 2-D profile and a 1-D cross-section of the electrical field are shown for a bias just above the breakdown voltage (5% overbias)." (Section 3.1). At the stated 13.3 V simulated breakdown voltage, breakdown and 5% overbias correspond to 13.3 V and 13.965 V, respectively. The effect on the result is unclear.
- **Reporting and transparency:** Noted. Generation-map figure references and panel descriptions are inconsistent. Conflicts of interest are disclosed, data are available upon reasonable request, and code availability is not stated.
  - Conflict of interest: declared · Data availability: declared
- **Reference integrity:** Clean. 41 of 41 checkable references verified
  - 42 references in manuscript
  - 1 have no canonical index record — counted, but not index-checkable
  - 4 references confirmed by manual review
  - References not verified automatically are resolved manually within 24 hours.

## Post-publication record

- **Status:** Clean
- **Summary:** No retraction or expression of concern found in Crossref (includes Retraction Watch).
- **Last checked:** 2026-11-25