#reportingHeadline efficiency omits its unusable bias regime
The Abstract highlights PDE above 75%, but the 76% peak requires high excess bias. Section 3.3 states that dark counts obstruct practical operation above approximately 10% excess bias and block the predicted PDE above 50%.
↳ Abstract; Section 3.3, Fig. 5
#methodological rigourExperimental comparison validates only part of performance
The experimental check concerns dark counts from one device, not optical PDE. Simulated and measured breakdown voltages differ by 2 V, and DCR agreement uses a literature-derived surface-trap density on a relative excess-bias scale.
↳ Section 3.2, Fig. 4(d)
#methodological rigourUnity carrier collection lacks a quantitative bound
The PDE calculation assumes complete collection from neutral core and rib regions without a quantitative sensitivity bound. This leaves uncertainty in the efficiency prediction, particularly given the substantial interface-trap contribution to the noise model.
↳ Section 2.3, Eqs. 5–7; Section 3.2