#reportingHeadline power contradicts the measured range
The abstract states 10 mW per wavelength, but Section 3 reports 6.9–10.1 mW across only three characterised wavelengths. The peak result therefore does not establish the stated per-wavelength specification across the tuning range.
↳ Abstract; Section 3, Figure 3
#methodological rigourMissing controls prevent isolated booster attribution
The two ridges share a parallel electrical connection, and no booster-off or unboosted reference measurement isolates amplification from cavity optimisation. The reported output demonstrates the combined device rather than quantifying the booster's separate gain.
↳ Section 2; Section 3, current–power discussion and final paragraph
#methodological rigourCalibration and device replication remain underspecified
Eight coupons were printed, but the tested-device count and device-to-device variation are not reported. Fiber-to-waveguide power de-embedding and key cavity-model parameters are also insufficiently specified for reproducing the quantitative interpretation.
↳ Section 2, transfer-printing paragraph; Section 3, Figures 3–5 and Equations 1–2