## Key claims

1. The implementation of a fast-converging iterative algorithm allows for parameter extraction using a 100 µm delay-length MZI from the bar port transmission spectrum, without ambiguity regarding interference order.
   - Support: Tentative
   - Type: Primary finding
   - Basis: order selection depends on a thickness prior and mean-level validation rather than independent device-level confirmation
   - Location: Section 8, Conclusions; Sections 4.4, 6.3
2. the implementation of the new mapping method reduces the error to ∆wmapping =0.006 nm and ∆tmapping =0.002 nm.
   - Support: Supported
   - Type: Secondary
   - Basis: simulated round-trip inversion supports numerical mapping precision rather than fabricated-device dimensional accuracy
   - Location: Section 4.3
3. This advancement not only enhances extraction accuracy but also enables the acquisition of high-precision parameters through a single compact device
   - Support: Tentative
   - Type: Secondary
   - Basis: unpaired physical validation and dominant database and sidewall-angle errors limit the claimed accuracy improvement
   - Location: Section 8, Conclusions
4. utilizing Li’s data as the mapping database results in an extracted waveguide width that is approximately 4 nm narrower and a thickness that is about 2.4 nm thicker compared to using Franta’s data.
   - Support: Supported
   - Type: Secondary
   - Basis: direct sensitivity calculations compare the two material-index databases
   - Location: Section 7.1, paragraph 2
5. ∆wrandom = ±1.89 nm
   - Support: Tentative
   - Type: Secondary
   - Basis: the error model combines components with an unexplained aggregation and uncertainty-scale convention
   - Location: Section 7.4, total error

## Strengths

- **Compact extraction with small numerical mapping errors** A single 100 µm-delay MZI supports the extraction workflow, and the iterative mapping exercise reports width and thickness errors of 0.006 nm and 0.002 nm on simulated inputs. These figures characterize numerical inversion rather than total measurement accuracy.
  - Dimension: contribution
  - Location: Sections 4.2–4.4
- **Documented measurements include optical artifact screening** The experiment spans 17 designed widths across eight dies with temperature-controlled spectral measurements. Database-artifact checks and cross-port screening address identifiable sources of extraction error.
  - Dimension: methodological rigour
  - Location: Sections 3.2, 5 and 6.1
- **Physical limitations receive quantitative contextual treatment** The analysis separates material-database sensitivity, sidewall-angle sensitivity and the allowable thickness window. It also explains why larger thickness variation requires a shorter MZI delay and reduced extraction precision.
  - Dimension: positioning
  - Location: Sections 7.1, 7.3 and 7.5

## Limitations

- **Absolute accuracy lacks matched device validation** Ellipsometry and CD-SEM references come from separate metrology structures rather than the measured MZI arms. Agreement between ensemble averages therefore does not establish device-level dimensional accuracy, and simulated mapping errors do not substitute for that benchmark.
  - Dimension: methodological rigour
  - Location: Sections 2.1, 4.3 and 6.3–6.4
- **Conclusions overstate order certainty and accuracy** The claim of extraction without interference-order ambiguity exceeds a fit guided by an assumed thickness and checked against mean thickness. The broader accuracy claim also exceeds Section 7.5's stated limits on absolute accuracy and random width-error improvement.
  - Dimension: reporting
  - Location: Sections 6.2–6.3, 7.5 and 8
- **Random uncertainty totals lack an explained convention** Section 7.4 reports ±1.89 nm width and ±0.06 nm thickness errors while describing a sum whose component bounds approach 3.789 nm and 0.129 nm. A half-range interpretation could explain the factor of two, but the uncertainty scales and conversion are not specified.
  - Dimension: methodological rigour
  - Location: Section 7.4

## Reliability checks

Caveats (4 of 4 checks).

- **Results check:** Noted
  - "For the random error, we believe it should be the sum of the three random errors mentioned above, which can be given by: ∆wrandom = ±1.89 nm" (Section 7.4, total error) vs "∆w∆α=1◦= 3.61 nm" (Section 7.4, error components). The printed component bounds give width and thickness sums approaching 0.173 + 3.61 + 0.006 = 3.789 nm and 0.090 + 0.037 + 0.002 = 0.129 nm, approximately twice the reported totals, but do not specify a common uncertainty scale or a half-range conversion. The effect on the result is unclear.
- **Reporting and transparency:** Noted. An unedited disclosure-template instruction remains in the Conclusions alongside a completed conflict-of-interest declaration. Data are available on reasonable request, without an identified suspicious availability claim.
  - Conflict of interest: declared · Data availability: declared
- **Reference integrity:** Clean. 9 of 9 checkable references verified
  - 10 references in manuscript
  - 1 have no canonical index record — counted, but not index-checkable
  - 2 references confirmed by manual review
  - References not verified automatically are resolved manually within 24 hours.

## Post-publication record

- **Status:** Clean
- **Summary:** No retraction or expression of concern found in Crossref (includes Retraction Watch).
- **Last checked:** 2026-11-25