# Enhanced Fano resonances in a silicon nitride photonic crystal nanobeam-assisted micro ring resonator for dual telecom band operation

- **DOI:** [10.1364/oe.504912](https://doi.org/10.1364/oe.504912)
- **Rating:** Limited (2.9 out of 5)
- **Verdict:** A dual-band silicon-nitride resonator demonstration establishes tunable Fano lineshapes, but incomplete comparative characterization limits its claimed performance advantages.
- **Framework version:** v5.13
- **Pipeline version:** v0.4
- **Evaluation date:** 2026-11-25
- **Evaluation page:** https://www.nabu.science/paper/10.1364%2Foe.504912

## Key claims

1. Our findings show that the fabricated PhCN-MRR results in increased asymmetric resonances for TM-like mode [at the O-band wavelengths] compared with TE-like mode operation in the C-band.
   - Support: Tentative
   - Type: Primary finding
   - Basis: wavelength and polarization change together without equivalent tabulated TM asymmetry metrics
   - Location: Abstract; Section 4.2, Figures 6 and 7
2. The asymmetry q is clearly increasing as NH increase with a ratio of 0.2037/0.0016 (see Table 2) [for the TE-like mode in the C-band with gy = 0.250 µm].
   - Support: Supported
   - Type: Secondary
   - Basis: the three selected resonance fits show increasing q without replication or parameter uncertainty
   - Location: Section 4.1, Table 2, Figure 6(c-e)
3. From the experimental results shown here, we estimate that by introducing the Fano line shape we increase the SR [slope rate] by a preliminary factor of 1.54 with respect to the Lorentzian.
   - Support: Tentative
   - Type: Secondary
   - Basis: no experimental Lorentzian control or explicit analytical benchmark establishes the estimated factor
   - Location: Section 4.3
4. The fabricated device can achieve experimental high-Q factors and Fano asymmetry parameter q (<0.4) over a wide range of wavelengths in the C-band by using the TE-like mode
   - Support: Tentative
   - Type: Secondary
   - Basis: quantitative extraction covers selected resonances near 1564 nm rather than a documented broad-wavelength performance range
   - Location: Section 5, Conclusions
5. The impact of the asymmetry on the slope rate of the resonance will improve proportionally the sensitivity and limit of detection of the fabricated device as a refractive index sensor
   - Support: Tentative
   - Type: Secondary
   - Basis: air-cladded transmission measurements do not establish index sensitivity or noise-limited detection performance
   - Location: Conclusions

## Strengths

- **Simulation and fabrication form an integrated workflow** Eigenmode and FDTD calculations are connected to fabricated silicon-nitride devices and optical transmission measurements across two telecom operating regimes.
  - Dimension: methodological rigour
  - Location: Sections 3–4; Figures 2–7
- **Geometric sweeps demonstrate tunable resonance behavior** The study varies nanobeam hole count and coupling gap rather than reporting a single configuration. Table 2 documents increasing fitted asymmetry across three selected C-band resonances.
  - Dimension: contribution
  - Location: Sections 4.1–4.2; Table 2
- **Relevant literature defines the device extension** The discussion connects the design to prior Fano microring configurations and O-band TM-mode sensing, making its incremental device contribution identifiable.
  - Dimension: positioning
  - Location: Introduction; Conclusions; references 9, 12–16 and 29

## Limitations

- **Selected resonances lack independent sampling information** The number of independent devices and resonances per condition is not stated, and fitted q, Q and slope-rate uncertainties are not reported. This limits generalization beyond the selected examples.
  - Dimension: methodological rigour
  - Location: Table 2; Figure 6(c-e); Section 4.2
- **Slope improvement lacks a demonstrated baseline** The preliminary 1.54-fold estimate has neither an experimental Lorentzian reference nor an explicit calculation from fitted parameters. It does not establish proportional sensitivity or detection-limit gains without index-response and noise measurements.
  - Dimension: methodological rigour
  - Location: Section 4.3; Conclusions
- **Headline comparison exceeds the comparative characterization** TM-like and TE-like operation are compared across different wavelength bands and measurement conditions without equivalent tabulated TM metrics. The abstract presents a firmer asymmetry advantage than this comparison establishes.
  - Dimension: reporting
  - Location: Abstract; Sections 4.1–4.2; Table 2

## Reliability checks

Caveats (4 of 4 checks).

- **Results check:** Noted. One reported value does not reconcile, but the key claims do not rest on it.
  - Minor reporting notes (1):
    - "Q-factor decreased from 2 · 10^3 to 1.5 · 10^3 with a reduction in the ER" (Section 4.1, paragraph on Fig. 6(c-e)) vs "Q 2026.1214 2309.4868 1527.06" (Table 2, row 'Q'). Comparing the endpoint summary with Table 2 shows that Q first increases from 2026.1214 to 2309.4868 and then decreases to 1527.06. The result itself is unaffected.
- **Reporting and transparency:** Noted. Two unit typographical errors occur in the device descriptions. Conflict of interest is disclosed and underlying data are offered upon reasonable request.
  - Conflict of interest: declared · Data availability: declared
- **Reference integrity:** Clean. 32 of 32 checkable references verified
  - 33 references in manuscript
  - 1 have no canonical index record — counted, but not index-checkable
  - 7 references confirmed by manual review
  - References not verified automatically are resolved manually within 24 hours.

## Post-publication record

- **Status:** Clean
- **Summary:** No retraction or expression of concern found in Crossref (includes Retraction Watch).
- **Last checked:** 2026-11-25