#methodological rigourCoupling equation lacks a reproducible numerical match
Substituting the stated confinement factors into Eq. (2), with an assumed effective index of 3.25, gives approximately 405–1821 cm⁻¹ rather than the reported low-coupling range. The overlap interpretation remains unresolved, limiting quantitative theoretical validation.
↳ Section 2, Eq. (2), Fig. 1(e)-(f); Section 3, Fig. 7
#reportingLoss and robustness wording exceeds documentation
The Abstract presents approximately 2 dB/cm loss without a described measurement basis, and the Conclusion calls the process proven robust despite single-chip replication. The structural-equivalence assertion also extends beyond the inverted-grating comparisons presented.
↳ Abstract; Section 2; Section 3, Fig. 6 discussion; Conclusion
#methodological rigourLow-coupling extraction lacks reported fit uncertainty
At 1 mm length, Eq. (1) gives approximately 0.64 nm even at zero coupling, close to the reported 0.68 nm result. Full-spectrum fitting offers additional information, but missing parameter uncertainties and goodness-of-fit measures limit assessment of extraction precision.
↳ Section 2, Eq. (1); Section 3, Figs. 4–5 and fitting description