# Plasma proteins facilitates placental transfer of polystyrene particles.

- **DOI:** [10.1186/s12951-020-00676-5](https://doi.org/10.1186/s12951-020-00676-5)
- **Rating:** Sound (3.1 out of 5)
- **Verdict:** Human placental perfusion links protein-containing media to nanoparticle distribution and corona remodeling, but cannot isolate corona-specific effects on transfer.
- **Framework version:** v5.13
- **Pipeline version:** v0.4
- **Evaluation date:** 2026-11-13
- **Evaluation page:** https://www.nabu.science/paper/10.1186%2Fs12951-020-00676-5

## Key claims

1. Human plasma incubated with PS-particles of 80 nm and subsequent formed protein corona enhanced the transfer across the human placenta compared to PS-corona formed by bovine serum albumin and dextran which served as a control.
   - Support: Tentative
   - Type: Primary finding
   - Basis: higher fetal concentrations accompany higher maternal concentrations and recovery, without separating transfer from retention
   - Location: Abstract, Results
2. the protein corona formed by human albumin significantly induced the transfer of PS-particles across the tissue compared to the formed IgG-corona.
   - Support: Tentative
   - Type: Secondary
   - Basis: unequal protein concentrations and free-medium effects prevent attribution specifically to the albumin corona
   - Location: Abstract, Results
3. We found 129 different proteins on PS-particles in plasma medium which were isolated before perfusion. The relative abundancy of proteins changed significantly on particles which crossed the placenta (93 different proteins).
   - Support: Tentative
   - Type: Secondary
   - Basis: four-replicate compartment comparisons characterize recovered coronas but cannot locate compositional change specifically during barrier crossing
   - Location: Results, Increased abundancy of albumin and immunoglobulin on PS-particles in the fetal compartment
4. the initial composition of PS-particles in the maternal circulation is not predictive for their transfer characteristics and their functionality once beyond the placental barrier
   - Support: Tentative
   - Type: Secondary
   - Basis: predictive performance and post-transfer functionality were not directly tested
   - Location: Conclusion

## Strengths

- **Human tissue model with explicit viability checks** Dual ex vivo placental perfusion preserves an intact human barrier under flow. Nine stated acceptance criteria include antipyrine transfer, metabolic measures and fetal backpressure.
  - Dimension: methodological rigour
  - Location: Methods, Dual ex vivo perfusion of a placental cotyledon
- **Compartment proteomics extends the transfer measurements** Particle-associated proteins were characterized before perfusion and after recovery from maternal and fetal circuits. This adds compositional evidence to the concentration measurements and identifies candidates for follow-up.
  - Dimension: contribution
  - Location: Results, Increased abundancy of albumin and immunoglobulin; Figure 3
- **Conflicting prior transfer results receive explanation** The Discussion compares its lower baseline transfer with earlier placental perfusion work, identifying albumin concentration and maternal and fetal flow rates as relevant experimental differences.
  - Dimension: positioning
  - Location: Discussion, final paragraph

## Limitations

- **Media comparisons cannot isolate corona effects** Protein identity, concentration and free-medium composition change together, while fetal concentrations are compared despite differing maternal concentrations. Recovery of 86.7% in plasma versus 59.4% in control also leaves medium-dependent loss unresolved without a reported cell-free circuit control.
  - Dimension: methodological rigour
  - Location: Table 1; Methods, Perfusion media; Results, Figures 2, 4 and 5
- **Central conclusions exceed the tested comparisons** The albumin comparison does not isolate a corona-specific mechanism, and predictive performance and post-transfer functionality were not directly tested. The Conclusion additionally invokes cellular-pathway deregulation without pathway measurements.
  - Dimension: reporting
  - Location: Abstract; Results, Plasma albumin drives the PS-particle transfer; Conclusion
- **Small groups lack reported allocation safeguards** The IgG comparison uses three placentas against five in the other perfusion groups. Randomized allocation and blinded outcome assessment are not reported, leaving uncertainty about between-placenta differences.
  - Dimension: methodological rigour
  - Location: Methods, Dual ex vivo perfusion of a placental cotyledon; Figures 2 and 4

## Reliability checks

Caveats (4 of 4 checks).

- **Results check:** Noted. One reported value does not reconcile, but the key claims do not rest on it.
  - Minor reporting notes (1):
    - Descriptive: "subsequently incubated for 15 min at a concentration of 400 g/ml with the respective medium to allow protein corona formation." (Methods, Zeta potential and particle size determination for the particles) vs "PS-particle stock solution, [1.2 ml of 1% (w/v)] was incubated with (i) 26 ml human female plasma" (Methods, Perfusion media). A 1% w/v stock contains 0.01 g/ml, so the reported 400 g/ml incubation concentration is 40,000 times the stock concentration and cannot result from its dilution. → Conclusion holds
- **Reporting and transparency:** Noted. The supplied text describes experimental use of human placental tissue without an ethics-approval or donor-consent declaration. Proteomics data availability is declared through PRIDE identifier PXD018160.
  - Ethics approval: not stated · Data availability: declared
- **Reference integrity:** Clean
  - 81 references in manuscript
  - 81 of 81 checkable references found in an index
  - References not verified automatically are resolved manually within 24 hours.

## Post-publication record

- **Status:** Clean
- **Summary:** No retraction or expression of concern found in Crossref (includes Retraction Watch).
- **Last checked:** 2026-11-13