# Dynamic Enhanced Magnetic Resonance Imaging versus Ultrasonic Diffused Optical Tomography in Early Diagnosis of Breast Cancer.

> **Reliability concern:** This paper was retracted on 2023-02-14. See notice: 10.1155/2023/9853726.

- **DOI:** [10.1155/2022/4834594](https://doi.org/10.1155/2022/4834594)
- **Rating:** Limited (2.7 out of 5)
- **Verdict:** Incremental single-centre diagnostic accuracy comparison of MRI and DOT for breast cancer, undermined by inadequate statistical methodology for its comparative claims.
- **Framework version:** v5.0
- **Pipeline version:** v0.4
- **Evaluation date:** 2026-06-01
- **Evaluation page:** https://www.nabu.science/paper/10.1155%2F2022%2F4834594

## Strengths

- **Appropriate pathological reference standard with both modalities** All patients received puncture or surgical pathology confirmation within two weeks of imaging, and both MRI and DOT were applied to the same cohort, enabling direct paired comparison against a valid gold standard.
  - Dimension: methodological rigour
  - Location: Methods §§2.1, 2.4
- **Detailed imaging protocol enabling reproducibility assessment** The MRI scanning parameters (sequences, TR, TE, flip angle, layer thickness, contrast injection protocol) and DOT procedure are described with sufficient technical detail for partial replication.
  - Dimension: methodological rigour
  - Location: Methods §§2.2, 2.3
- **Multi-parameter quantitative characterisation of both modalities** The paper reports quantitative DCE-MRI parameters (Ktrans, Kep, Ve) and DOT parameters (THC) alongside morphological features, providing multi-dimensional characterisation rather than relying on a single diagnostic criterion.
  - Dimension: contribution
  - Location: Results §§3.2, 3.3; Tables 2-4

## Limitations

- **Statistical methods inadequate for paired diagnostic comparisons** The Methods section describes only chi-square and t-tests, but the study's central claims compare sensitivity, specificity, and AUC across modalities applied to the same patients. Appropriate methods for paired diagnostic data (e.g., McNemar's test, DeLong's test) are neither described nor referenced.
  - Dimension: methodological rigour
  - Location: Methods §2.5; Results §§3.4-3.5
- **Clinical recommendation disproportionate to evidence base** The conclusion recommends ultrasonic DOT as 'the primary screening method for early breast cancer,' but this recommendation is based on a single-centre retrospective study of 110 patients with no prospective validation, cost-effectiveness analysis, or external replication.
  - Dimension: contribution
  - Location: Conclusion; Discussion §4.3
- **Single reader with no blinding or reliability assessment** MRI diagnosis was performed by one physician using an undefined 'double blind method.' No inter-rater reliability statistics are reported, and blinding to DOT results and pathology during MRI interpretation is not confirmed, which is a critical gap in diagnostic accuracy studies.
  - Dimension: methodological rigour
  - Location: Methods §2.2

## Reliability checks

Concerns (4 of 4 checks).

- **Internal coherence:** Noted. The paper is internally consistent at a surface level — numbers in the abstract match results, directional claims are consistent, and no statistical impossibilities were detected. However, the conclusion recommends DOT as a 'primary screening method' based on evidence that does not support such a strong clinical recommendation, constituting overclaiming beyond the study design.
- **Research conduct:** Noted. Ethics approval is declared by reference to the Declaration of Helsinki but no specific IRB or ethics committee approval number is provided, making it declared-but-unverified. No conflict of interest statement is present. Data availability is claimed but not repository-backed.
- **Reference integrity:** Clean. All 23 cited references resolved to real publications via PubMed, Crossref, or OpenAlex.
  - References not verified automatically are resolved manually within 24 hours.

## Post-publication record

- **Status:** Concern
- **Summary:** This paper was retracted on 2023-02-14. See notice: 10.1155/2023/9853726.
- **Last checked:** 2026-10-17