Reliability concern: This paper was retracted on 2023-10-11. See notice: 10.1155/2023/9756936.

  • Snapshot
  • Key Claims
  • Strengths & Limitations
  • Commentary
  • From the Authors
  • Author Note / Field Feedback
  • Dimension breakdown
  • Readiness
Report #NBU-B332C032·Framework v5.0·Pipeline v0.4·Evaluated 01 Jun 2026·OECD: 3.2 Clinical medicine·Subfield: Radiology, Nuclear Medicine and Imaging·Basis: Full text·Type: Cross-sectional study

Intelligent Algorithm-Based CT Imaging for Evaluation of Efficacy of Docetaxel Combined with Fluorouracil on Patients with Gastric Cancer.

Chen et al.Chen, Wang, Ding et al.·2021·Journal of healthcare engineering·10.1155/2021/1040374 ↗

In brief

A dual-thread chemotherapy comparison and CT-segmentation report whose core claims are undermined by conflicting methods, missing validation metrics, and unverifiable statistics.

ReliabilityConcerns4 of 4 checks completeRead the 3 entries ↓
Abstract

The study focused on the dual-source computed tomography (CT) images segmented by the decision tree algorithm, to explore the efficacy of docetaxel combined with fluorouracil therapy on gastric patients undergoing chemotherapy. In this study, 98 patients with gastric cancer who were treated in the hospital were selected as the research subjects. The decision tree algorithm was applied to segment dual-source CT images of gastric cancer patients. The decision tree is established according to the feature ring and the segmentation position. The machine inductively learns from the decision tree to extract the features of the CT image to obtain the optimal segmentation boundary. The observation group was treated with docetaxel combined with fluorouracil, and the control group was treated with docetaxel combined with tegafur gimeracil oteracil potassium capsules. The general data of the two groups of patients were comparable and not statistically significant (P > 0.05). The two groups were compared for clinical efficacy, physical status, KPS score, improvement rate, and adverse drug reactions after treatment. The results showed that the improvement rate of physical fitness in the observation group was 38.78%, and the improvement rate in the control group was 18.37%. The total effective rate in the observation group was 42.85%, and the total effective rate in the control group was 36.73%. Obviously, the curative effect and improvement rate of physical fitness in the observation group were significantly better than those in the control group (P < 0.05). In conclusion, the decision tree algorithm proposed in this study demonstrates superb capabilities in feature extraction of CT images. The machine inductively learns from the decision tree to extract the features of the CT image to obtain the optimal segmentation boundary. The effect of docetaxel combined with fluorouracil is better than that of docetaxel combined with tegafur gimeracil oteracil potassium capsules.

Strengths · Limitations

Strengths

#methodological rigour

Clear patient eligibility criteria

Inclusion and exclusion criteria are explicitly enumerated, which at least defines the intended clinical population for the comparison.

↳ Methods §2.1

#contribution

Detailed algorithm formalism provided

The decision-tree/ID3 formulation and feature descriptions are laid out with equations and a described feature set, enabling readers to understand the intended computational approach at a conceptual level.

↳ Methods §2.4–2.6

#reporting

Concrete outcome counts reported

The response-category counts (CR/PR/SD/PD) and KPS improvement/stability/decline counts are stated, which provides a minimal basis for checking arithmetic consistency.

↳ Results §3.2; Results §3.4

Limitations

#methodological rigour

Contradictory group assignment description

The paper states grouping was based on contrast-agent concentration, but elsewhere defines groups by chemotherapy regimen, undermining the study design and interpretability.

↳ Methods §2.1 vs Methods §2.2; Abstract

#contribution

No quantitative segmentation validation

Segmentation is described qualitatively and visually, but no accuracy metrics, ground truth comparison, or validation protocol is reported to support the algorithm claims.

↳ Results §3.1; Abstract; Conclusion §5

#methodological rigour

Unverifiable statistical significance claims

Multiple results are described as 'significantly' different with P < 0.05, but the manuscript does not report test statistics, exact p-values, or confidence intervals for key comparisons.

↳ Statistics §2.7; Results §3.2–3.4

Does this match your read? Add your assessment ↓

Withdrawn — shown for reference only

Nabu Commentary

The paper’s central limitation is internal: it describes group assignment by contrast-agent concentration (Methods §2.1) while implementing and interpreting a chemotherapy-regimen comparison (Methods §2.2; Results §3.2–3.4). The imaging algorithm is presented with mathematical detail (Methods §2.4–2.6) but the results section does not provide quantitative segmentation performance or validation, making the algorithm claims non-verifiable (Results §3.1). Clinical conclusions are expressed with strong language and thresholded P-values without accompanying test outputs or uncertainty estimates (Results §3.2–3.4; Abstract). Additional anomalies—such as placeholder reference text in Discussion §4 and drug batch numbers predating the study period in Methods §2.2—further reduce confidence in the report as a record of primary research.

Check another paper

Free · About 5 minutes · Research preview

Author Note / Field Feedback

Nabu’s assessment, alongside the field’s view.

Are you an author of this paper?

Dimension breakdown

Study Quality

Very Limited1.5

Confidence high
Contribution
1.4

The paper claims a decision-tree CT segmentation advance plus evidence that one chemotherapy regimen outperforms another, but neither is supported at the level needed to constitute a clear contribution. The algorithm is described mathematically yet not evaluated with quantitative segmentation metrics, and the clinical effect size is modest and not reported with verifiable statistics.

Results §3.1; Results §3.2; Abstract; Conclusion §5

"demonstrates superb capabilities"

Methodological Rigour
1.4

Design-execution fit is compromised by a contradiction in how groups were formed (contrast-agent concentration vs drug regimen) and by repeated significance claims without reporting test statistics, p-values, or confidence intervals. The algorithm component also omits core execution details (validation split, ground truth, performance metrics), limiting assessment of whether it was competently implemented.

Methods §2.1–2.3; Statistics §2.7; Results §3.1–3.4

"According to different concentrations of contrast agents"

Reporting
2.0

The manuscript has conventional section structure, but the central argument is hard to follow because the imaging and treatment threads are repeatedly blended without a clear analytical bridge. Unresolved contradictions and placeholder text in the discussion reduce readability and interpretability.

Methods §2.1–2.2; Discussion §4; Abstract

"[Author] et al. [21]"

Positioning
1.7

Background and discussion cite general gastric-cancer and chemotherapy points, but the work is not positioned against a clearly defined comparative-efficacy evidence base or against established CT segmentation benchmarks. The limitations focus on small sample size and generic segmentation imperfection while omitting key design/reporting limitations.

Introduction §1; Discussion §4; Conclusion §5

"the sample size is small"

Lower confidence on Reporting, Positioning — domain match limited.

Reliability

Concerns4 of 4 checks


Internal CoherenceConcern

The manuscript’s clinical comparison and imaging-algorithm threads are not coherently linked, and the study design description conflicts on how groups were formed. Core claims of algorithm performance and treatment superiority are asserted without the quantitative evidence needed to verify them.

Research ConductConcern

Conduct and reporting signals are insufficiently verifiable, and multiple anomalies (e.g., anachronistic drug batch numbers) raise data authenticity concerns beyond routine transparency limitations.

Flags: 2 declared / 5 total

Reference IntegrityClean

All 21 cited references resolved to real publications via PubMed, Crossref, or OpenAlex.

References not verified automatically are resolved manually within 24 hours.

Post-Publication RecordConcern

This paper was retracted on 2023-10-11. See notice: 10.1155/2023/9756936.

Last checked: 17 Oct 2026

Sources: Crossref (incl. Retraction Watch) ✓

Readiness

Where this paper’s evidence sits on the path from initial observation to real-world use.

Foundational

The CT algorithm remains at a qualitative demonstration stage because segmentation performance is not reported with quantitative metrics or validation details. The chemotherapy comparison is not presented in a way that supports clinical translation because statistical support is not verifiable beyond threshold claims.

Results §3.1–3.4; Statistics §2.7; Abstract

"P < 0.05"

Report an issue →

AI-generated, human-governed. Something look off? Contact us to request a review.

Keep reading

Related evaluations

Other papers Nabu has evaluated blind, starting with the same field.

  1. How Does Diagnostic Accuracy Evolve with Increased Breast MRI Experience?

    Wu, Alikhassi, Curpen · 2023 · Clinical medicine

    Primary claim

    Diagnostic accuracy improved exponentially with increased MRI experience (definition B, OR of 1.27 and 1.61 for 5 and 10 years, respectively, p = 0.03 for both).

    Tentative
    Study quality
    Limited2.3
    Reliability
    Caveats
  2. General cognitive function and the brain's structural connectome

    Buchanan, Moodie, Batziou, et al. · 2026 · Basic medicine

    Primary claim

    g is supported by a widely distributed white matter network whose macroscopic wiring capacity, microstructural organisation, and age sensitivity contribute in distinct ways.

    Tentative
    Study quality
    Sound3.6
    Reliability
    Caveats
  3. The Dementias Platform UK PET/MR harmonisation and test-retest study: assessment of PET repeatability and reproducibility across the national network

    Markiewicz, Thompson, Wardlaw, et al. · 2026 · Clinical medicine

    Primary claim

    CL values across 74 scans showed excellent test-retest agreement (ICC = 0.968), improving to 0.987 after exclusion of one attenuation correction related outlier.

    Supported
    Study quality
    Sound3.3
    Reliability
    Caveats

How the rubric works →