# Sequential diagnosis with language models

- **DOI:** [10.1126/science.aeh7930](https://doi.org/10.1126/science.aeh7930)
- **Rating:** Limited (2.8 out of 5)
- **Verdict:** SDBench advances cost-aware sequential diagnostic evaluation, but untested public-case contamination limits interpretation of its headline physician comparison.
- **Framework version:** v5.10
- **Pipeline version:** v0.4
- **Evaluation date:** 2026-10-22
- **Evaluation page:** https://www.nabu.science/paper/10.1126%2Fscience.aeh7930

## Key claims

1. DxO without budget constraints achieved an average diagnostic accuracy of 80.3% at a mean cost of $4979 per ED case.
   - Support: Supported
   - Type: Primary finding
   - Basis: directly reported ED benchmark outcome under a text-only oracle interface rather than real clinical encounters
   - Location: Results, Emergency medicine studies
2. DxO with GPT-5 established a new Pareto frontier that outperformed the participating physicians at every cost or accuracy level.
   - Support: Tentative
   - Type: Secondary
   - Basis: public-CPC exposure and an individual-generalist comparator constrain the frontier claim
   - Location: Results, Clinicopathological conference studies
3. Across all of the models tested, DxO orchestration boosted the diagnostic accuracy on the ED cases and CPC cases by an average of 4.4 and 7.9 percentage points, respectively.
   - Support: Tentative
   - Type: Secondary
   - Basis: comparison with minimally prompted models does not isolate orchestration-specific gains against a stronger baseline
   - Location: Results, Studies of model capabilities and errors

## Strengths

- **Sequential evaluation includes diagnostic test costs** SDBench measures information gathering and diagnostic stopping decisions alongside accuracy and cumulative estimated testing costs, extending evaluation beyond a complete vignette supplied at once.
  - Dimension: contribution
  - Location: Introduction; Results, benchmark description
- **Multiple datasets and model generations evaluated** The evaluation combines CPC and independently sourced ED cases, a held-out CPC physician set, multiple model families, and a GPT-5.5 rerun without prompt changes.
  - Dimension: methodological rigour
  - Location: Results, Clinicopathological conference studies; Emergency medicine studies; Studies of model capabilities and errors
- **Clinical scope restrictions are explicitly stated** The paper distinguishes controlled diagnostic performance from superiority over specialists, teams, or real-world care, and explains the missing safety and longitudinal dimensions.
  - Dimension: reporting
  - Location: Introduction; Discussion, limitations

## Limitations

- **Public case exposure remains experimentally unchecked** The CPC benchmark uses published NEJM cases without a reported contamination evaluation. Holding cases out of engineering does not establish that the underlying models had not encountered them during pretraining.
  - Dimension: methodological rigour
  - Location: Results, Clinicopathological conference studies; Discussion
- **Minimal prompting limits orchestration gain attribution** The reported orchestration gains are measured against minimally prompted models. This establishes a difference between the evaluated configurations, not a clean isolation of orchestration-specific benefits against a stronger comparator.
  - Dimension: methodological rigour
  - Location: Results, Studies of model capabilities and errors
- **Simulation constrains transfer to clinical practice** Text-only oracle interaction, pathological case selection, and US chargemaster pricing leave substantial uncertainty about performance and cost trade-offs in routine care. The Judge does not assess therapeutic safety or longitudinal outcomes.
  - Dimension: application pathway
  - Location: Discussion, limitations

## Reliability checks

Caveats (4 of 4 checks).

- **Results check:** Clean. The reported numbers and statistics are consistent with the stated results.
- **Reporting and transparency:** Noted. The main text does not declare ethics approval or consent for the physician study and leaves the DxO CPC evaluation subset unclear. Competing interests and dataset access conditions are disclosed.
  - Conflict of interest: declared · Ethics approval: not stated · Data availability: declared · Code availability: declared
- **Reference integrity:** Clean. 9 of 9 checkable references verified
  - 12 references in manuscript
  - 3 have no canonical index record — counted, but not index-checkable
  - 8 references confirmed by manual review
  - References not verified automatically are resolved manually within 24 hours.

## Post-publication record

- **Status:** Clean
- **Summary:** No retraction or expression of concern found in Crossref (includes Retraction Watch).
- **Last checked:** 2026-10-22