# A Radiation-Tolerant 25.6-Gb/s High-Speed Transmitter in 28-nm CMOS With a Tolerance of 1 Grad

- **DOI:** [10.1109/tns.2024.3440010](https://doi.org/10.1109/tns.2024.3440010)
- **Rating:** Sound (3.5 out of 5)
- **Verdict:** A 25.6-Gb/s transmitter demonstrates tolerance beyond 1 Grad, but restricted operating validation prevents its results from establishing guaranteed error-free LHC deployment.
- **Framework version:** v5.13
- **Pipeline version:** v0.4
- **Evaluation date:** 2026-11-25
- **Evaluation page:** https://www.nabu.science/paper/10.1109%2Ftns.2024.3440010

## Key claims

1. The [25.6-Gbit·s−1 high-speed transmitter] circuit achieves a total ionizing dose (TID) tolerance above 1 Grad, which aligns with the future large hadron collider (LHC) detector upgrade requirements.
   - Support: Supported
   - Type: Primary finding
   - Basis: direct irradiation evidence under PRBS7 test conditions with unstated independent device replication
   - Location: Abstract
2. The assessed SEE immunity confirmed the effectiveness of the implemented TMR strategy, guaranteeing error-free operation of the designed HST in the LHC environment
   - Support: Tentative
   - Type: Secondary
   - Basis: disabled interleaving and absent end-to-end FEC validation leave the deployment guarantee unestablished
   - Location: Section V, Conclusion
3. The correct operation of the designed [25.6-Gbit·s−1] high-speed transmitter macro was confirmed for the power supply voltage variation of ±10% from nominal 0.9 V and over the specified TID range.
   - Support: Tentative
   - Type: Secondary
   - Basis: pattern-restricted validation and required recalibration limit the unqualified statement of correct operation
   - Location: Section V, paragraph 1
4. the protected circuit shows a cross section reduced by more than two orders of magnitude to 2.33 × 10−14 cm2, which results in 30-bit errors per day.
   - Support: Supported
   - Type: Secondary
   - Basis: environment-specific projection from heavy-ion measurements without reported uncertainty on the fitted error rate
   - Location: Section IV-B
5. An error-free transition of PRBS7 sequence was achieved, while for longer patterns, higher DDJ values lead to transition errors.
   - Support: Supported
   - Type: Secondary
   - Basis: directly observed pattern-dependent behavior with an unquantified error-free BER limit
   - Location: Section III-B

## Strengths

- **High speed transmission at ultrahigh dose** The 28-nm prototype demonstrates 25.6-Gb/s transmission with tolerance beyond 1 Grad under its stated test conditions, extending the data-rate and dose targets of the cited HEP transmitters.
  - Dimension: contribution
  - Location: Introduction; Section IV-A; Table III
- **Failure mechanisms receive direct experimental investigation** The measurements identify a 180-MHz power-delivery resonance, compare fixed and repeated duty-cycle calibration, and investigate low-voltage bit corruption above 1.4 Grad.
  - Dimension: methodological rigour
  - Location: Sections III-B and IV-A; Figs. 5 and 7–9
- **Protected and unprotected radiation responses compared** Heavy-ion testing directly compares operation with triple modular redundancy enabled and disabled. The analysis distinguishes residual transient bursts and projects a substantially reduced error rate for the specified detector environment.
  - Dimension: methodological rigour
  - Location: Section IV-B; Fig. 10

## Limitations

- **Conclusion exceeds the demonstrated operating scope** The conclusion guarantees error-free LHC operation despite documented longer-pattern errors and an ion-test configuration that did not establish end-to-end FEC-corrected performance. Its supply-range operation statement also omits the PRBS7 qualification.
  - Dimension: positioning
  - Location: Sections III-B, IV-B and V
- **Device replication and BER precision unstated** The number of independently tested or irradiated chips is not reported. Error-free transmission is stated without the bit count or confidence bound needed to quantify the demonstrated BER limit.
  - Dimension: methodological rigour
  - Location: Sections III-A and IV-A–B
- **Complete operating configuration remains insufficiently tested** Error-free transmission is restricted to PRBS7, while longer patterns encounter power-delivery-induced jitter. TID BER testing used non-TMR operation without pre-emphasis, and heavy-ion testing disabled interleaving, leaving complete protected-operation validation incomplete.
  - Dimension: methodological rigour
  - Location: Sections III-B and IV-A–B

## Reliability checks

No concerns (3 of 4 checks).

- **Results check:** Clean. The reported numbers and statistics are consistent with the stated results.
- **Reporting and transparency:** Clean. Funding is disclosed, and no research-conduct concern is established for this hardware characterization study. Data, code and other transparency declarations cannot be established from the supplied reporting.
- **Reference integrity:** Clean
  - 28 references in manuscript
  - 22 of 22 checkable references found in an index
  - 6 have no canonical index record — counted, but not index-checkable
  - 3 mistyped DOIs matched to the cited work by its details
  - 1 reference confirmed by manual review
  - References not verified automatically are resolved manually within 24 hours.

## Post-publication record

- **Status:** Not checked
- **Summary:** Post-publication record check unavailable at this time.
- **Last checked:** 2026-11-25