A Radiation-Tolerant 25.6-Gb/s High-Speed Transmitter in 28-nm CMOS With a Tolerance of 1 Grad

2024·IEEE Transactions on Nuclear Science·10.1109/tns.2024.3440010 ↗

Primary claim

The [25.6-Gbit·s−1 high-speed transmitter] circuit achieves a total ionizing dose (TID) tolerance above 1 Grad, which aligns with the future large hadron collider (LHC) detector upgrade requirements.

Supported · direct irradiation evidence under PRBS7 test conditions with unstated independent device replication
In brief

A 25.6-Gb/s transmitter demonstrates tolerance beyond 1 Grad, but restricted operating validation prevents its results from establishing guaranteed error-free LHC deployment.

ReliabilityNo concerns3 of 4 checks completeSee what was checked ↓
Possible — the claim's weakest requirement is that the effect exists at all. Experimental. Every point below is traceable to a quoted passage, but this forecast has not yet been validated against known replication outcomes.
Abstract

This paper presents a 25.6 Gbit s−1high-speed transmitter (HST) manufactured using 28nm CMOS technology. The HST macro-block includes an all-digital phase-locked loop (ADPLL), duty cycle corrector (DCC) circuit, data pattern generator, serializer, and a driver capable of driving the differential 100Ω line as well as a silicon photonics (SiPh) ring modulator (RM). The design adopts various radiation hardening techniques, such as triple modular redundancy (TMR), physical circuit spacing, and protection against radiation-induced leakage. The circuit achieves a total ionizing dose (TID) tolerance above 1 Grad, which aligns with the future large hadron colider (LHC) detector upgrade requirements. In this paper, the architecture of the HST based on the LC tank-based ADPLL, half-rate serializer, and the source-series-terminated (SST) output driver included in the prototype chip is described. The experimental results are reported, including general evaluation as well as the radiation characterization of the HST.

Key Claims

Primary finding · Supported

The [25.6-Gbit·s−1 high-speed transmitter] circuit achieves a total ionizing dose (TID) tolerance above 1 Grad, which aligns with the future large hadron collider (LHC) detector upgrade requirements.

Possible — the claim's weakest requirement is that the effect exists at all. Experimental. Every point below is traceable to a quoted passage, but this forecast has not yet been validated against known replication outcomes.

direct irradiation evidence under PRBS7 test conditions with unstated independent device replication

Abstract
Quote verified
Secondary · Tentative

The assessed SEE immunity confirmed the effectiveness of the implemented TMR strategy, guaranteeing error-free operation of the designed HST in the LHC environment

disabled interleaving and absent end-to-end FEC validation leave the deployment guarantee unestablished

Section V, Conclusion
Quote verified
Secondary · Tentative

The correct operation of the designed [25.6-Gbit·s−1] high-speed transmitter macro was confirmed for the power supply voltage variation of ±10% from nominal 0.9 V and over the specified TID range.

pattern-restricted validation and required recalibration limit the unqualified statement of correct operation

Section V, paragraph 1
Quote verified
Secondary · Supported

the protected circuit shows a cross section reduced by more than two orders of magnitude to 2.33 × 10−14 cm2, which results in 30-bit errors per day.

environment-specific projection from heavy-ion measurements without reported uncertainty on the fitted error rate

Section IV-B
Quote verified
Secondary · Supported

An error-free transition of PRBS7 sequence was achieved, while for longer patterns, higher DDJ values lead to transition errors.

directly observed pattern-dependent behavior with an unquantified error-free BER limit

Section III-B
Quote verified

Derived from the full evaluation — not a separate score.

Strengths · Limitations

Strengths

#contribution

High speed transmission at ultrahigh dose

The 28-nm prototype demonstrates 25.6-Gb/s transmission with tolerance beyond 1 Grad under its stated test conditions, extending the data-rate and dose targets of the cited HEP transmitters.

↳ Introduction; Section IV-A; Table III

#methodological rigour

Failure mechanisms receive direct experimental investigation

The measurements identify a 180-MHz power-delivery resonance, compare fixed and repeated duty-cycle calibration, and investigate low-voltage bit corruption above 1.4 Grad.

↳ Sections III-B and IV-A; Figs. 5 and 7–9

#methodological rigour

Protected and unprotected radiation responses compared

Heavy-ion testing directly compares operation with triple modular redundancy enabled and disabled. The analysis distinguishes residual transient bursts and projects a substantially reduced error rate for the specified detector environment.

↳ Section IV-B; Fig. 10

Limitations

#positioning

Conclusion exceeds the demonstrated operating scope

The conclusion guarantees error-free LHC operation despite documented longer-pattern errors and an ion-test configuration that did not establish end-to-end FEC-corrected performance. Its supply-range operation statement also omits the PRBS7 qualification.

↳ Sections III-B, IV-B and V

#methodological rigour

Device replication and BER precision unstated

The number of independently tested or irradiated chips is not reported. Error-free transmission is stated without the bit count or confidence bound needed to quantify the demonstrated BER limit.

↳ Sections III-A and IV-A–B

#methodological rigour

Complete operating configuration remains insufficiently tested

Error-free transmission is restricted to PRBS7, while longer patterns encounter power-delivery-induced jitter. TID BER testing used non-TMR operation without pre-emphasis, and heavy-ion testing disabled interleaving, leaving complete protected-operation validation incomplete.

↳ Sections III-B and IV-A–B

Does this match your read? Add your assessment ↓

Nabu Commentary

The 25.6-Gb/s prototype establishes a useful high-dose transmitter demonstration through electrical characterization, X-ray irradiation and heavy-ion testing. Its diagnostic measurements connect observed degradation to power delivery, duty-cycle calibration and low-voltage timing behavior. Experimental coverage remains narrower than complete deployment validation because error-free operation is pattern-restricted and the radiation tests use different protection configurations. The conclusion's error-free LHC guarantee therefore outweighs the otherwise substantive literature positioning and limitation analysis in determining the Positioning score.

Evaluate another paper

Free · About 5 minutes · Research preview

Author Note / Field Feedback

Nabu’s assessment, alongside the field’s view.

Are you an author of this paper?

Dimension breakdown

Evidence Score

Out of 5
012345
3.5±0.2

Contribution
3.9

The integrated 25.6-Gb/s transmitter and radiation campaign establish a measurable advance over the cited lower-rate, lower-dose HEP transmitters. Restricted pattern coverage limits deployment readiness without removing the demonstrated high-dose contribution.

Introduction; Sections III-B and IV; Table III
Methodological Rigour
3.5

Electrical measurements, controlled X-ray irradiation and protected/unprotected heavy-ion tests support the experimental argument and diagnose specific failure mechanisms. Unstated device replication, limited BER precision and incomplete validation of the complete protection chain constrain generalization.

Sections III-A–B and IV-A–B; Figs. 5, 7–10
Reporting
3.5

The architecture-to-measurements sequence and explicit failure-mode descriptions make the technical argument followable. The supply-range summary does not carry forward the pattern restriction stated in the measurement section.

Sections II–IV; Section V, paragraph 1
Positioning
2.8

The paper relates its targets to predecessor hardware and traces power-integrity and calibration limitations to operational consequences. Its concluding guarantee nevertheless exceeds those documented limitations, setting the score below the otherwise substantive positioning and discussion.

Introduction; Sections III-B, IV-A–B and V; Table III

Reliability

No concerns3 of 4 checks


Results checkClean

The reported numbers and statistics are consistent with the stated results.

Reporting and transparencyClean

Funding is disclosed, and no research-conduct concern is established for this hardware characterization study. Data, code and other transparency declarations cannot be established from the supplied reporting.

Reference IntegrityClean

28 references in manuscript 22 of 22 checkable references found in an index 6 have no canonical index record — counted, but not index-checkable 3 mistyped DOIs matched to the cited work by its details 1 reference confirmed by manual review

References not verified automatically are resolved manually within 24 hours.

Post-Publication RecordNot checked

Post-publication record check unavailable at this time.

Last checked: 25 Nov 2026

Sources: Crossref (incl. Retraction Watch) ✓

Impact Profile

Impact areaProducts and technology · SDG 9
Type of advanceEmpirical
Route to useNamed
AdvanceExtends
CitationsFWCI 0.6
Policy · patentNot yet traced
ReachedNot reachedNot assessable or unverified
ReadinessPiloted
Foundational
Controlled
Piloted
Validated
Implementable
FoundationalImplementable

A single prototype chip was irradiated and shown error-free at 25.6 Gbit/s up to 1 Grad, which is proof of concept rather than validated multi-site or routine operation.

From the paper
“guaranteeing error-free operation of the designed HST in the LHC environment, making it suitable for use in future HEP experiments”

The paper names the setting that would use the transmitter, namely the LHC environment and future HEP experiments, for error-free data transmission.

Pathway

CERN and HEP detector designers would integrate this transmitter into HL-LHC detector readout optical links for future experiments.

Barrier

The prototype's power delivery network degrades signal integrity and must be fixed in a next chip revision before deployment in actual detectors.

Evaluated 25 Nov 2026 · GBD 2023 · glm_v1_3_3 · impact_profile_v1_3_3

Report an issue →

AI-generated, human-governed. Something look off? Contact us to request a review.

Keep reading

Related evaluations

Other papers Nabu has evaluated blind, starting with the same field.

  1. Densely integrated low polarization dependent 8 × 8 optical switch for optical network applications

    2026 · Electrical engineering, electronic engineering, information engineering

    Primary claim

    Multiple measured paths show promising results: gain over 20 dB, PDG under 3 dB, and high OSNR over 40 dB across the full C-band.

    Tentative
    Evidence Score
    2.8±0.1
    Reliability
    Caveats
  2. A Comparison of Plasmonic Modulator Structures in the O- and C-Band for the 400G/Lane IM/DD Era

    2026 · Electrical engineering, electronic engineering, information engineering

    Primary claim

    All four modulators offer a compact footprint, net-data rates above 400 Gbit/s, and an electro-optic bandwidth above 100 GHz.

    Supported
    Evidence Score
    3.1±0.1
    Reliability
    Caveats
  3. Waveguide Geometry–Driven Trade‐Offs in Resonant Cavity Sensor Performance

    2026 · Physical sciences

    Primary claim

    Despite its lowest sensitivity, the ridge resonator delivers the best performance (Q = 3.5 × 10^5 , LOD = 4.2 × 10− 8 RIU) through superior stability.

    Tentative
    Evidence Score
    2.9±0.1
    Reliability
    Concerns

How the rubric works →