# Microsphere-Integrated Photonic Crystal Sensors for Spatially-Resolved Refractive Index Measurement

- **DOI:** [10.1109/lpt.2025.3585430](https://doi.org/10.1109/lpt.2025.3585430)
- **Rating:** Sound (3.0 out of 5)
- **Verdict:** Microsphere-assisted fringe imaging demonstrates spatial refractive-index sensing, but unquantified accuracy and resolution leave the instrument at proof-of-concept stage.
- **Framework version:** v5.13
- **Pipeline version:** v0.4
- **Evaluation date:** 2026-11-25
- **Evaluation page:** https://www.nabu.science/paper/10.1109%2Flpt.2025.3585430

## Key claims

1. it [the proposed refractometer] is a simple and eﬀective tool for measuring RI with spatially resolved micrometer-scale resolution.
   - Support: Tentative
   - Type: Primary finding
   - Basis: sphere-scale sampling is demonstrated without independently measured spatial resolution or quantitative RI accuracy
   - Location: Abstract
2. For [4.9 µm PS microspheres], the stripe pattern has a magniﬁcation factor of 2.32×, 2.04×, 1.65× and 1.21× in water, ethanol, ethylene glycol, and MIO, respectively.
   - Support: Supported
   - Type: Secondary
   - Basis: four-liquid imaging supports the reported magnifications without quantified between-sphere or trial variability
   - Location: Fig. 4 discussion
3. The developed refractometer has a good compatibility with commercial optical microscopes, and can be used as a label-free, point-of-care device for rapid detection of various liquids.
   - Support: Tentative
   - Type: Secondary
   - Basis: microscope compatibility is demonstrated without point-of-care deployment testing
   - Location: Conclusion, Page 4, column 1, paragraph 2
4. The validity of the proposed method is verified by measuring both standard uniform liquids and the dynamic process of oil-water merging
   - Support: Tentative
   - Type: Secondary
   - Basis: demonstrations lack quantitative accuracy and replication estimates needed to establish measurement validity
   - Location: Abstract
5. the RI spatial distribution over the whole FOV can be eﬀectively determined based on the frequency of the patterns
   - Support: Tentative
   - Type: Secondary
   - Basis: the qualitative boundary map lacks quantified local accuracy under sphere-to-sphere variation
   - Location: Conclusion; Fig. 5

## Strengths

- **Optical integration enables spatial liquid sensing** Microsphere lenses magnify a patterned substrate, and local Fourier analysis converts the fringe patterns into a spatial RI map. The water–oil boundary demonstrates the intended sensing workflow.
  - Dimension: contribution
  - Location: Figs. 1 and 5
- **Four liquids connect modelling and measurement** PS-sphere magnification is measured across water, ethanol, ethylene glycol and immersion oil and compared with a relationship derived from FDTD focal lengths. This provides a physical basis for the observed liquid-dependent fringe changes.
  - Dimension: methodological rigour
  - Location: Eqs. 1–2; Fig. 4
- **Device and processing sequence remain followable** The optical configuration is specified, and the figures trace the workflow from single-sphere windowing through spectrum extraction to RI mapping.
  - Dimension: reporting
  - Location: Fig. 2; Eqs. 3–4; Fig. 5

## Limitations

- **Measurement uncertainty and replication remain unreported** The reported magnifications have no stated microsphere or independent-trial counts and no dispersion estimates. Quantitative RI accuracy, repeatability and independently measured spatial resolution are not established.
  - Dimension: methodological rigour
  - Location: Figs. 4–5
- **Averaging does not validate local mapping** The text acknowledges sphere-size variation and substrate misalignment and proposes averaging measurements from spheres in the same liquid. It does not establish how those errors affect a single-sphere spatial map, where averaging across a boundary sacrifices localization.
  - Dimension: positioning
  - Location: Fig. 4 discussion; Fig. 5
- **Performance and deployment claims exceed testing** The abstract describes validity as verified and spatial resolution as micrometer-scale without quantitative validation of those capabilities. The point-of-care conclusion also extends beyond the demonstrated microscope-mounted measurement workflow.
  - Dimension: reporting
  - Location: Abstract; Fig. 2; Conclusion

## Reliability checks

Caveats (4 of 4 checks).

- **Results check:** Noted
  - "The magniﬁcation factor of the pattern is 3.2× in water and 2.9× in MIO, respectively." (Fig. 3 discussion, magnification) vs "focal length, referring to the distance between the focal point and the center of the microsphere, is 24.5 µm in MIO and 36.7 µm in water." (Fig. 3 discussion, FDTD focal lengths). Water has both the larger reported magnification and the longer focal length, contrary to the immediately following statement that a longer focal length generally gives smaller magnification. The effect on the result is unclear.
- **Reporting and transparency:** Clean. No reporting or transparency concern is established from the supplied text. Referenced supplementary material outside the supplied content does not establish a concern.
  - Data availability: not stated · Code availability: not stated
- **Reference integrity:** Clean. 23 of 23 checkable references verified
  - 23 references in manuscript
  - References not verified automatically are resolved manually within 24 hours.

## Post-publication record

- **Status:** Clean
- **Summary:** No retraction or expression of concern found in Crossref (includes Retraction Watch).
- **Last checked:** 2026-11-25