# Vertical Coupling Between Waveguides and Optical Fibers Utilizing Polarization Gratings

- **DOI:** [10.1109/lpt.2024.3352278](https://doi.org/10.1109/lpt.2024.3352278)
- **Rating:** Sound (3.0 out of 5)
- **Verdict:** Liquid-crystal post-processing provides a vertical-coupling proof of concept, but the fabricated device omits the quarter-wave plate required for full vertical redirection.
- **Framework version:** v5.13
- **Pipeline version:** v0.4
- **Evaluation date:** 2026-11-25
- **Evaluation page:** https://www.nabu.science/paper/10.1109%2Flpt.2024.3352278

## Key claims

1. It is demonstrated that such a LCPG can be used to transform standard Si photonic grating couplers into vertical light coupling devices which can greatly simplify photonic packaging.
   - Support: Tentative
   - Type: Primary finding
   - Basis: fabrication omits the quarter-wave plate needed for full vertical redirection and does not test packaging simplification
   - Location: Section V, Conclusion
2. [In 2D FEM simulation,] when the [quarter-wave plate (QWP)] and [liquid crystal polarization grating (LCPG)] layers are combined, the light [from the Si grating coupler] goes only to the perpendicular direction.
   - Support: Tentative
   - Type: Secondary
   - Basis: the idealized two-dimensional simulation is limited by an unresolved inconsistency between the printed grating period and diffraction angle
   - Location: Section II, paragraph 2, Fig. 2(c)-(e)
3. Experimental data shows a 4.2dB variance [between 12° without LCPG and 0° with LCPG], revealing an additional 1.2dB loss with actual LCPG.
   - Support: Supported
   - Type: Secondary
   - Basis: the reported device comparison supports the loss arithmetic but lacks replication counts and alignment uncertainty
   - Location: Section IV, Characterization, Figure 8
4. the light beam, initially emitted at 12◦, has now been redirected to 0◦and 24◦.
   - Support: Tentative
   - Type: Secondary
   - Basis: the angle-resolved comparison lacks quantified repeatability and its stated subtraction order leaves the direction of the changes uncertain
   - Location: Section IV, Characterization, Figure 7(d) interpretation

## Strengths

- **Post-processing concept tested on foundry chips** A spin-coated liquid-crystal polarization grating is integrated with a conventional planarized silicon grating coupler. The fabricated device and coupling measurements move the concept beyond a simulation-only proposal.
  - Dimension: contribution
  - Location: Sections III–IV, Figs. 3–8
- **Controlled configurations and thickness-dependent optical measurements** The simulations compare bare, LCPG-only, and QWP-plus-LCPG configurations. Profilometry and angle- and wavelength-resolved measurements examine how deposited thickness affects the optical response.
  - Dimension: methodological rigour
  - Location: Section II, Fig. 2; Section IV, Figs. 5–8
- **Fabrication obstacle explained alongside potential remedies** The fabrication section explicitly explains why the photoalignment solvent prevented QWP integration and cites alternative photoalignment materials that could enable multilayer devices.
  - Dimension: positioning
  - Location: Section III, paragraph 2, references 25–26

## Limitations

- **Headline framing exceeds the fabricated device** Full vertical redirection requires the QWP-plus-LCPG stack, but the experiment uses an LCPG alone and reports a 4.2 dB penalty relative to angled coupling. The abstract and conclusion blur this distinction, and packaging simplification is not experimentally tested.
  - Dimension: reporting
  - Location: Abstract; Section III; Section IV, Fig. 8; Section V
- **Replication and alignment uncertainty remain unreported** Device counts, repeated measurements, and uncertainty estimates are not supplied for the thickness and optical measurements. Repositioning the fiber at every angle introduces an unquantified repeatability issue for interpreting the reported loss differences.
  - Dimension: methodological rigour
  - Location: Section IV, Figs. 5–8
- **Quantitative conventions leave key interpretations unresolved** The printed diffraction equation and 13.6 µm period imply an incident-angle magnitude of approximately 6.55°, not 12°, for vertical output. The stated subtraction order also conflicts with interpreting positive peaks near 10 dB as increased transmission at 0° and 24°.
  - Dimension: methodological rigour
  - Location: Section II, grating-period calculation; Section IV, Fig. 7(d)

## Reliability checks

Caveats (4 of 4 checks).

- **Results check:** Noted
  - "sin θout = (m λ Λ) + sin θin (with m = 1), yielding Λ = 13.6 µm." (Section II, FEM Simulation, grating-period calculation). Using the printed equation, λ = 1.55 µm and Λ = 13.6 µm, vertical output requires sin θin = −0.11397, or θin ≈ −6.55°, not an incident-angle magnitude of 12°. The effect on the result is unclear.
  - "Γ = 2π λ (ne −no)d = π 2 , equates to d = 4.3 µm." (Section II, FEM Simulation, retardation calculation). Substitution of the printed indices, wavelength and thickness into Γ = 2π(ne − no)d/λ gives approximately 3.12 rad, not π/2. The result itself is unaffected.
  - "by subtracting the transmitted power of samples containing LCPGs from the power transfer of unaltered samples." (Section IV, Characterization, power-subtraction description) vs "the power transfer at 0◦and 24◦is comparable and forms two peaks at around 10dB" (Section IV, Characterization, Figure 7(d) interpretation). If the plotted dB differences use the stated unaltered-minus-LCPG order, positive values indicate lower LCPG-sample transmission at those angles rather than an increase attributed to redirection; the actual convention is uncertain. The effect on the result is unclear.
- **Reporting and transparency:** Clean. No research-conduct concern is established for this bench photonics study. The absence of data, code, or other standard declarations does not independently establish a transparency concern.
  - Data availability: not stated · Code availability: not stated
- **Reference integrity:** Clean. 26 of 26 checkable references verified
  - 26 references in manuscript
  - 4 references confirmed by manual review
  - References not verified automatically are resolved manually within 24 hours.

## Post-publication record

- **Status:** Clean
- **Summary:** No retraction or expression of concern found in Crossref (includes Retraction Watch).
- **Last checked:** 2026-11-25