# Chip-Scale Fabry-Pérot Resonators for Blue Wavelength Photonics

- **DOI:** [10.1109/jphot.2026.3681978](https://doi.org/10.1109/jphot.2026.3681978)
- **Rating:** Limited (2.9 out of 5)
- **Verdict:** Blue-wavelength silicon-nitride Fabry–Pérot resonators achieve a measured Q of 6500, but incomplete optical characterization limits broader performance claims.
- **Framework version:** v5.13
- **Pipeline version:** v0.4
- **Evaluation date:** 2026-11-26
- **Evaluation page:** https://www.nabu.science/paper/10.1109%2Fjphot.2026.3681978

## Key claims

1. The fabricated [Fabry-Pérot] cavities achieve a full-width at half-maximum (FWHM) of 70 pm and a loaded quality factor (Ql) of 6.5 × 10^3 at 454 nm.
   - Support: Supported
   - Type: Primary finding
   - Basis: a measured resonance supports the device-level result despite unreported replication and linewidth uncertainty
   - Location: Abstract; Section III-B, Fig. 3(b)
2. These results show that the FP resonators can provide a better Q factor compared to MRRs.
   - Support: Tentative
   - Type: Secondary
   - Basis: the compared devices differ in geometry and coupling without isolating architecture effects or device variability
   - Location: Section III-B, final paragraph
3. Fig. 2(b) shows the transmission spectrum of the measured DBR with N = 200 layers, each with a period of P = 0.129 µm, resulting in a measured optical bandgap of 4 nm width
   - Support: Supported
   - Type: Secondary
   - Basis: a single transmission spectrum supports the stopband width but lacks reference normalization and replication
   - Location: Section III-A, Fig. 2(b)
4. the FSR decreases as [FP] cavity length increases
   - Support: Supported
   - Type: Secondary
   - Basis: the reported cavity-length sweep supports the trend without quantified uncertainty or device counts
   - Location: Section III.B; Fig. 3(a)

## Strengths

- **Measured blue resonance with consistent headline metrics** The FP cavity achieves a reported 70 pm linewidth and loaded Q of 6500 at 454 nm. The wavelength-to-linewidth ratio agrees with the stated Q.
  - Dimension: contribution
  - Location: Abstract; Section III-B, Fig. 3(b)
- **Fabrication recipe supports interpretation of device execution** The paper specifies LPCVD deposition, electron-beam exposure, development, and plasma-etch parameters, with SEM characterization of the patterned structures.
  - Dimension: methodological rigour
  - Location: Section II, Fig. 1(e)–(f)
- **Relevant framing of visible waveguide loss tradeoffs** The introduction distinguishes scattering and absorption limitations and explains the trade-off between low-loss dilute modes and high-confinement waveguides.
  - Dimension: positioning
  - Location: Introduction, discussion of references [3], [18], [26], and [27]

## Limitations

- **Device replication and measurement variability remain unspecified** The central resonance and geometric sweeps do not state how many devices or chips were measured or provide uncertainty and device-to-device variation. This limits reproducibility and precision judgments.
  - Dimension: methodological rigour
  - Location: Sections III-A–III-B, Figs. 2–3
- **Optical calibration leaves efficiency and loss unresolved** Transmission is reported in arbitrary units without a reference-waveguide normalization or propagation-loss baseline, limiting assessment of the claimed coupling efficiency above 90%. The ring's Q components also imply approximately 4976 rather than the reported 5300, although its ordering below the FP device survives.
  - Dimension: methodological rigour
  - Location: Sections III-A–III-B, Figs. 2(b), 3(b), and 3(d)
- **Abstract performance language exceeds demonstrated device evidence** The assertion of a reliable path to high-performance passive components is not backed by reproducibility or propagation-loss measurements. The measured device pair also does not establish general FP superiority over ring resonators.
  - Dimension: reporting
  - Location: Abstract; Section III-B, final paragraph

## Reliability checks

Caveats (4 of 4 checks).

- **Results check:** Noted
  - "yielding a loaded quality factor (Ql) of 5.3 × 10^3, with Qc = 1.2 × 10^4 and Qi = 8.5 × 10^3." (Section III.B, MRR resonance). Assuming the standard relation 1/Ql = 1/Qc + 1/Qi gives (12000 × 8500)/(12000 + 8500) = 4975.61, below the reported 5300 but still below the FP value of 6500. The result itself is unaffected.
- **Reporting and transparency:** Noted. Section II duplicates polarization-mode labels and points to Fig. 2(b)–(d) for schematics located in Fig. 1(b)–(d). These are reporting errors without a demonstrated effect on the measured resonance.
  - Conflict of interest: not stated · Data availability: not stated
- **Reference integrity:** Clean. 39 of 40 checkable references verified
  - 41 references in manuscript
  - 1 have no canonical index record — counted, but not index-checkable
  - 3 references confirmed by manual review
  - References not verified automatically are resolved manually within 24 hours.

## Post-publication record

- **Status:** Clean
- **Summary:** No retraction or expression of concern found in Crossref (includes Retraction Watch).
- **Last checked:** 2026-11-26
