# Temperature Sensing Diode in InP-Based Photonic Integration Technology

- **DOI:** [10.1109/jphot.2024.3374266](https://doi.org/10.1109/jphot.2024.3374266)
- **Rating:** Sound (3.4 out of 5)
- **Verdict:** Foundry-compatible InP diodes demonstrate local temperature sensing, but unquantified accuracy and device variation limit deployment confidence.
- **Framework version:** v5.13
- **Pipeline version:** v0.4
- **Evaluation date:** 2026-11-25
- **Evaluation page:** https://www.nabu.science/paper/10.1109%2Fjphot.2024.3374266

## Key claims

1. A linear relationship between temperature and voltage was observed in these [InP p-i-n diode] sensors, with measured sensitivities ranging from −1.1 to −2.1 mV/K.
   - Support: Supported
   - Type: Primary finding
   - Basis: thermistor-referenced measurements over 16–60 °C support the relationship without quantifying fit residuals or device-level variation
   - Location: Section V, p. 6; Table I, p. 4
2. The Q1.25-bulk sensors performed better than the Q1.55-MQW sensors, exhibiting higher sensitivities. Specifically, they achieved a measured sensitivity of −2.1 mV/K in a compact junction area of 10 × 30 µm.
   - Support: Supported
   - Type: Secondary
   - Basis: the measured stack comparison supports higher sensitivity without quantifying between-device variation or uncertainty
   - Location: Section V, p. 6; Table I, p. 4
3. As illustrated in Fig. 9(b, d), neither type of temperature sensor exhibited optically induced changes [during 1 µs pulsed on-chip laser operation].
   - Support: Tentative
   - Type: Secondary
   - Basis: a single laser geometry without a quantified detection limit establishes only a bounded optical-null observation
   - Location: Section IV-B, p. 5; Abstract; Section V, p. 6
4. Fig. 10(b, d) show that both sensors tracked the laser activation during slow pulsing [0.5 s pulses], thereby capturing the heat dissipation and temperature fluctuations.
   - Support: Supported
   - Type: Secondary
   - Basis: slow-pulse voltage responses support local heat tracking without an independent local temperature reference
   - Location: Section IV-B, p. 5–6; Fig. 10

## Strengths

- **Temperature sensing without foundry process changes** Existing Q1.55-MQW and Q1.25-bulk p-i-n building blocks provide temperature-sensitive devices without modifying the fabrication process. The comparison establishes a practical InP-platform implementation rather than a new sensing principle.
  - Dimension: contribution
  - Location: Section III, Fig. 1; Section IV-A, Table I
- **Referenced calibration compares four sensor variants** Thermistor-referenced measurements compare two layer stacks and two junction sizes at multiple current densities. Figure 6 and Table I support a linear voltage–temperature response over 16–60 °C and sensitivities from −1.1 to −2.1 mV/K.
  - Dimension: methodological rigour
  - Location: Section IV-A, Figs. 4–6 and Table I
- **Pulse timing separates optical and thermal responses** Fast 1 µs and slow 0.5 s laser pulses distinguish a rapid optical-interference test from a slower heating response. The slow-pulse experiment demonstrates local response to an on-chip heat source.
  - Dimension: methodological rigour
  - Location: Section IV-B, Figs. 7–10

## Limitations

- **Device counts and measurement uncertainty remain unreported** The sensitivity results lack device and repeat counts, uncertainty estimates and fit residuals. Additional dies and fabrication runs are described qualitatively, leaving the claimed consistency and device-to-device spread unquantified.
  - Dimension: methodological rigour
  - Location: Section IV-A, Fig. 6, Table I and following paragraph
- **Immunity wording exceeds the optical test** The Abstract and Conclusion generalize from one laser configuration at approximately 500 µm separation and 1 mW waveguide power. Without a quantitative detection limit, the null response does not establish general stray-light immunity.
  - Dimension: reporting
  - Location: Abstract; Section IV-B, Figs. 7–9; Section V
- **Deployment calibration requirements receive limited interpretation** The discussion does not establish absolute temperature accuracy or explain how device offsets and calibration requirements affect practical deployment. Experimental characterization covers 16–60 °C, while wider operation is supported by simulation rather than measurement.
  - Dimension: positioning
  - Location: Introduction; Section IV-A; Section V

## Reliability checks

Caveats (4 of 4 checks).

- **Results check:** Clean. The reported numbers and statistics are consistent with the stated results.
- **Reporting and transparency:** Noted. Cross-die and cross-run consistency is asserted qualitatively without device counts or quantitative supporting results.
  - Data availability: not stated · Code availability: not stated
- **Reference integrity:** Clean. 32 of 33 checkable references verified
  - 36 references in manuscript
  - 3 have no canonical index record — counted, but not index-checkable
  - 2 references confirmed by manual review
  - References not verified automatically are resolved manually within 24 hours.

## Post-publication record

- **Status:** Clean
- **Summary:** No retraction or expression of concern found in Crossref (includes Retraction Watch).
- **Last checked:** 2026-11-25