#methodological rigourDevice counts and measurement uncertainty remain unreported
The sensitivity results lack device and repeat counts, uncertainty estimates and fit residuals. Additional dies and fabrication runs are described qualitatively, leaving the claimed consistency and device-to-device spread unquantified.
↳ Section IV-A, Fig. 6, Table I and following paragraph
#reportingImmunity wording exceeds the optical test
The Abstract and Conclusion generalize from one laser configuration at approximately 500 µm separation and 1 mW waveguide power. Without a quantitative detection limit, the null response does not establish general stray-light immunity.
↳ Abstract; Section IV-B, Figs. 7–9; Section V
#positioningDeployment calibration requirements receive limited interpretation
The discussion does not establish absolute temperature accuracy or explain how device offsets and calibration requirements affect practical deployment. Experimental characterization covers 16–60 °C, while wider operation is supported by simulation rather than measurement.
↳ Introduction; Section IV-A; Section V