#methodological rigourCharacterization leaves important performance boundaries unresolved
Noise referral relies on simulated TIA gain, the zero-error observations lack a stated captured bit count, and coupling is measured only at 10 GHz. These results characterize one assembly rather than performance across devices and operating conditions.
↳ Electro-Optical Experiments; Fig. 4; Table 1
#reportingProcessing and deployment wording exceed demonstrated evidence
The setup reports AWG compensation while the eye-diagram paragraph says no equalization was used, without clarifying the distinction. The abstract also asserts low latency and switching-network suitability without corresponding latency or network tests.
↳ Abstracts; Electro-Optical Experiments, measurement setup and eye-diagram paragraphs
#positioningComparative positioning lacks integrated quantitative limits
The Introduction identifies relevant prior receivers but provides no structured comparison of sensitivity, noise and energy boundaries. The discussion does not integrate CDR exclusion and characterization limits into its system-level positioning.
↳ Introduction; Electro-Optical Experiments; Conclusions