#reportingVertical acceptance is attributed beyond measurement
The >6° vertical FoV is presented as an array property, but Fig. 4 characterizes a 15-µm reference coupler rather than the 85-µm array. The array's vertical acceptance therefore remains unestablished by that measurement.
↳ Abstract; Section III, Fig. 4; Section V
#methodological rigourConflicting opening angles obscure device identification
The abstract specifies 90° couplers, whereas Section II and Fig. 6 identify an 80° array. The measured horizontal response remains associated with the 80° structure, not an established characterization of the abstract's 90° design.
↳ Abstract; Section II; Section III, Fig. 6
#methodological rigourSingle angle testing limits system validation
Transmission uses a roughly 30-µm focused spot over 15 cm at one incidence angle, rather than demonstrating data reception across the array's horizontal FoV. Repeatability estimates and a reconciliation of simulation, passive-characterization and link conditions are also absent.
↳ Sections II–V; Figs. 3–6 and 10–11