#methodological rigourLoss extraction lacks an independent transmission control
The headline estimate subtracts about 6.97 dB of camera-derived propagation loss from about 7.59 dB of total insertion loss. Without a cut-back or equivalent independent reference, calibration offsets can materially alter the small residual.
↳ Section IV, Fig. 6
#methodological rigourThrough transmission identifies only the facet average
The two-interface measurement yields a combined coupling loss, whose halving estimates the mean rather than either facet individually. The printed equation omits that division, although adding it reproduces the rounded 0.31 dB/facet result.
↳ Section IV, coupling-loss calculation
#reportingUVC and scattering statements exceed reported evidence
The conclusion claims UVC operation despite a reported 320–430 nm low-loss range and measurements at 375 and 405 nm, outside UVC. The abstract also asserts significant scattering reduction without a quantified reference comparison.
↳ Abstract; Section IV, Fig. 6; Section V