# Optical-transition parameters of the silicon T center

- **DOI:** [10.1103/physrevapplied.22.064014](https://doi.org/10.1103/physrevapplied.22.064014)
- **Rating:** Strong (3.8 out of 5)
- **Verdict:** Silicon T-centre spectroscopy resolves disputed optical parameters and demonstrates electrical tuning, but absolute Stark coefficients retain unquantified field-calibration uncertainty.
- **Framework version:** v5.13
- **Pipeline version:** v0.4
- **Evaluation date:** 2026-11-26
- **Evaluation page:** https://www.nabu.science/paper/10.1103%2Fphysrevapplied.22.064014

## Key claims

1. [For the silicon T centre TX state] we find θp = (−7.7 ± 0.5)° [and] the deformation potential parameters are found to be b = −1.72 ± 0.12 [eV], d = −2.39 ± 0.14 [eV].
   - Support: Supported
   - Type: Primary finding
   - Basis: joint spectroscopy and DFT support parameters constrained partly by archival strain spectra and shared model assumptions
   - Location: Section II, p. 2 & Section IV, p. 3; Table I
2. Under a field of 125 kV/m, we observe up to 1.5 GHz shift, two orders of magnitude larger than the inhomogeneous linewidth.
   - Support: Supported
   - Type: Secondary
   - Basis: directly observed tuning with indirect field calibration and an imprecise linewidth comparison of approximately 38-fold
   - Location: Introduction; Sec. VII B
3. we find the g-factor values for the T centre TX state Hamiltonian to be |g1| = 1.226 ± 0.005 and |g2| = 0.005 ± 0.002.
   - Support: Supported
   - Type: Secondary
   - Basis: angle-resolved two-laser spectra constrain fitted parameters subject to shared Hamiltonian assumptions and archival strain inputs
   - Location: Section V.B.1, p. 4; Table I
4. Our model captures the linear and the quadratic behavior of this shift by a DC Stark effect.
   - Support: Supported
   - Type: Secondary
   - Basis: joint Stark fits reproduce both regimes with free misalignment angles, ambiguous orientation assignments and indirect field calibration
   - Location: Introduction; Sec. VII B; Fig. 6
5. fields of 1–1.2 MV/m applied along [001] would be required to tune across the full spectral range of photonically integrated T centres
   - Support: Tentative
   - Type: Secondary
   - Basis: approximately twentyfold extrapolation beyond measured [001] fields with unpropagated calibration uncertainty
   - Location: Sec. VIII Discussion

## Strengths

- **Complementary evidence constrains disputed optical parameters** Reanalyzed strain spectra, angle-resolved Zeeman spectroscopy and supercell DFT jointly constrain the defect potential. The fitted tilt angle of −7.7 ± 0.5° agrees with the DFT estimate of −8.10°.
  - Dimension: contribution
  - Location: Sections IV–V; Table I; Appendix B2; Figures 4 and 8
- **Screening controls support measured electrical tuning** The spectra demonstrate shifts up to 1.5 GHz. A dedicated pulse-frequency sweep identifies a stable regime above 500 Hz, addressing free-charge screening during the Stark measurements.
  - Dimension: methodological rigour
  - Location: Section VII; Figure 6; Appendix D; Figure 13
- **Device predictions retain important physical conditions** The branching-ratio analysis specifies linear dipole emission and explains why suppression of non-radiative and phonon-assisted decay is needed for high optical cyclicity.
  - Dimension: positioning
  - Location: Sections VI and VIII; Figure 5

## Limitations

- **Absolute field uncertainty remains outside coefficient errors** The internal field is estimated from a series-capacitor model using a 0.1 mm helium gap, without propagating geometry uncertainty. The quoted Stark-coefficient errors therefore omit a potentially consequential systematic contribution.
  - Dimension: methodological rigour
  - Location: Appendix B5d; Table I
- **Stark assignments depend on flexible modeling** The [001] fit requires a −13 ± 1° misalignment and averaging across five plausible line assignments. Dipole-sign assignment also relies on molecular calculations that neglect the bound exciton.
  - Dimension: methodological rigour
  - Location: Section VII.B; Appendices B5b and B6; Figures 11–12
- **Integrated tuning predictions exceed measured field range** The proposed 1–1.2 MV/m tuning fields extrapolate approximately twentyfold beyond the measured [001] range of about 60 kV/m. Their numerical precision is additionally limited by the unpropagated field-calibration uncertainty.
  - Dimension: positioning
  - Location: Sections VII.A and VIII; Appendix B5d

## Reliability checks

Caveats (3 of 4 checks).

- **Results check:** Noted
  - "Under a field of 125 kV/m, we observe up to 1.5 GHz shift, two orders of magnitude larger than the inhomogeneous linewidth." (Section I, p. 2) vs "Shifts of up to 1.5 GHz, an order of magnitude larger than the inhomogeneous linewidth, are observed." (Section VII.B, p. 5). Dividing the reported 1500 MHz shift by the approximately 40 MHz zero-field linewidth gives 37.5, whereas division by the approximately 130 MHz PLE linewidth gives approximately 11.5. The result itself is unaffected.
  - "Reference code is †[23] and ‡[24]." (Table I caption) vs "Ref. [27] (where only magnetic" (Appendix B 1). The comparison values b = −1.8 eV and d = −5.0 eV are attributed to [24] in Table I and [27] in Appendix B1; the caption's convention statement prevents establishing a separate sign error. The effect on the result is unclear.
- **Reporting and transparency:** Noted. The electric-field calculation attaches inappropriate units to relative permittivities and a normalized capacitance quantity, while its voltage ratios remain reproducible. No substantive conduct concern is established.
- **Reference integrity:** Noted. 51 of 51 checkable references verified
  - 53 references in manuscript
  - 2 have no canonical index record — counted, but not index-checkable
  - the reference list may be incompletely parsed; counts are indicative
  - 7 references confirmed by manual review
  - References not verified automatically are resolved manually within 24 hours.

## Post-publication record

- **Status:** Not checked
- **Summary:** Post-publication record check unavailable at this time.
- **Last checked:** 2026-11-26
