#methodological rigourOffset-free comparison changes source and device
The offset-free experiment changes repetition rate, pulse energy, pulse duration and waveguide width relative to the nonzero-offset experiment. Its absence of offset beats is consistent with the simulation, but does not isolate pump offset experimentally or quantify a residual-offset bound.
↳ Experiments; Figs. 3–4
#methodological rigourSuppression estimate assumes two dominant combs
The SSR estimator assumes two interleaved combs with high power contrast, while additional beat notes indicate at least three combs above 238 pJ. The reported 15 dB value at 1300 nm is therefore an approximate estimate rather than an exact line-by-line power ratio.
↳ Eqs. 1–3; Fig. 3(c)–(d)
#reportingSpectrum-wide link claim exceeds measured coherence
Narrow RF beats establish relative coherence within selected filtered bands. The conclusion's broader assertion of suitability for external phase-coherent links across the spectrum goes beyond that measurement scope.
↳ Experiments, coherence discussion; Conclusion