# Application of zero-noise-extrapolation-based quantum error mitigation to a silicon spin qubit

- **DOI:** [10.1103/925y-b4s1](https://doi.org/10.1103/925y-b4s1)
- **Rating:** Sound (3.4 out of 5)
- **Verdict:** Zero-noise extrapolation improves readout-corrected estimates on a silicon spin qubit, but missing uncertainty estimates limit confidence in the headline fidelities.
- **Framework version:** v5.13
- **Pipeline version:** v0.4
- **Evaluation date:** 2026-11-25
- **Evaluation page:** https://www.nabu.science/paper/10.1103%2F925y-b4s1

## Key claims

1. We then apply global folding-based zero-noise extrapolation to the state tomography and achieve a state fidelity of 99.96% (98.52%), compared to the unmitigated fidelity of 75.82% (82.16%) for different preparation states [|−Y⟩ and |X⟩].
   - Support: Tentative
   - Type: Primary finding
   - Basis: single-qubit tomography without fidelity uncertainties or complete sampling details, with most improvement attributable to readout correction
   - Location: Abstract, p. 2; Quantum state tomography, p. 10, Fig. 4(d)
2. Among the three noise amplification methods [in standard randomized benchmarking], the global folding method achieves the lowest error both in the low and high error regimes.
   - Support: Supported
   - Type: Secondary
   - Basis: benchmark comparisons favour global folding among the implemented protocols, with different extrapolation methods limiting attribution to amplification alone
   - Location: Randomized benchmarking, p. 8, Fig. 3(a)-(c)
3. As shown in Fig. 5 [gate set tomography], we observe a pronounced deviation from the Markovian assumptions as both the circuit depth and sequence length increase.
   - Support: Tentative
   - Type: Secondary
   - Basis: GST model-departure interpretation remains uncertain because the reported LLR threshold is not reconciled with the stated degrees of freedom
   - Location: Discussion, p. 10, Fig. 5
4. the zero-noise extrapolation technique is a versatile approach that is generally adaptable to quantum computing platforms with different noise characteristics
   - Support: Tentative
   - Type: Secondary
   - Basis: one silicon device and two shallow state preparations cannot establish general adaptability across platforms and noise characteristics
   - Location: Abstract; Conclusion
5. our results show the viability of achieving enhanced operational fidelities through ZNE, even in the presence of noise environments that pose challenges for precise characterization.
   - Support: Tentative
   - Type: Secondary
   - Basis: postprocessing improves estimates rather than demonstrating improved physical operations
   - Location: Conclusion

## Strengths

- **Silicon demonstration includes separate mitigation baselines** Tomography compares Raw, REM-only, and REM+ZNE estimates for two prepared states. These baselines identify an incremental improvement beyond readout correction on the tested device.
  - Dimension: contribution
  - Location: Quantum state tomography; Fig. 4(d)
- **Benchmarking and sampling choices are explicit** The amplification comparison uses 50 random Clifford sequences per point, 1000 repetitions, and bootstrap resampling. The tomography section explains the two-node Richardson choice and 3:1 sampling allocation through the bias–variance trade-off.
  - Dimension: methodological rigour
  - Location: Randomized benchmarking; Quantum state tomography; Figs. 3–4
- **Noise limitations inform the physical interpretation** The Discussion connects correlated charge noise and GST model departures to limits on mitigation performance. It identifies concrete remedies including frequency tracking, dynamical decoupling, alternative readout, and randomized compiling.
  - Dimension: positioning
  - Location: Introduction; Discussion; Fig. 5

## Limitations

- **Headline wording overattributes gains to extrapolation** REM alone raises the two fidelities from 75.82% and 82.16% to 95.69% and 91.76%, before ZNE reaches 99.96% and 98.52%. The Abstract and Conclusion omit that split, while claims of enhanced operational fidelity and general platform adaptability exceed the demonstrated improvement in postprocessed estimates.
  - Dimension: reporting
  - Location: Abstract; Quantum state tomography, Fig. 4(d); Conclusion
- **Tomography precision and comparison remain incompletely specified** The headline fidelities lack reported uncertainty estimates, complete QST shot counts, and independent repeat counts. The amplification comparison also changes extrapolation method between folding and pulse stretching, limiting attribution of the observed ranking to amplification alone.
  - Dimension: methodological rigour
  - Location: Quantum state tomography, Fig. 4(d); Randomized benchmarking, Fig. 3
- **Calibration and goodness-of-fit calculations need clarification** Appendix B reports approximately 1% initialization error from an energy ratio of approximately 9, whereas a two-level thermal-equilibrium calculation gives approximately 0.012%. Appendix C's LLR threshold of 17 is also unresolved against the stated chi-squared degrees of freedom, leaving the effects on fidelity precision and GST interpretation undetermined.
  - Dimension: methodological rigour
  - Location: Appendices B–C; Fig. 5 caption

## Reliability checks

Caveats (4 of 4 checks).

- **Results check:** Noted
  - "Zeeman splitting is equal to approximately 9 times the thermal energy; thus, we can calculate the false initialization probability to the excited state ~ 1% [74]." (Appendix B). Assuming two-level thermal equilibrium and using the rounded energy ratio, 1/(1 + exp(9)) ≈ 0.000123, or 0.012%, rather than approximately 1%; the effect on calibrated fidelity cannot be calculated. The effect on the result is unclear.
  - "when the LLR value exceeds the range (2Δ log 𝐿 > 17), the box is shown in shades of red on the logarithmic scale" (Appendix C, p. 13 and Figure 5 caption, p. 22) vs "where k is 61, 137, 254, 417, 585 for L = 1, 2, 4, 8, 16, respectively." (Figure 5 caption, p. 22). If the quoted degrees of freedom govern the same raw per-box LLR, its 95th-percentile threshold is approximately 80.2 already at k = 61, not 17; the per-box versus aggregated interpretation is unresolved. The effect on the result is unclear.
  - Minor reporting notes (1):
    - "primarily removed the readout error through REM and obtained an improved fidelity of 95.69% (91.76%)." (Quantum state tomography, p. 10) vs "The QST results show that REM significantly reduces the infidelities from 24.18% to 4.31% for the state |−Y⟩ and from 17.84% to 8.25% for the state |X⟩." (Discussion, p. 10). Subtracting the reported REM-only fidelity of 91.76% from 100% gives an infidelity of 8.24%, not 8.25%. The result itself is unaffected.
- **Reporting and transparency:** Clean. No research-conduct or transparency concern is established from the supplied text. Uncorroborated or absent availability and disclosure information is not treated as evidence of misconduct.
- **Reference integrity:** Noted. 73 of 75 checkable references verified
  - 75 references in manuscript
  - 3 references confirmed by manual review
  - Could not be verified automatically — queued for manual review:
    - Z. Chen et al., Exponential suppression of bit or phase errors with cyclic error correction, Nature 595, 383 (2021). (Crossref bibliographic top candidate ratio 0.37 — no plausible match)
    - R. Acharya et al., Suppressing quantum errors by scaling a surface code logical qubit, Nature 614, 676 (2023). (Crossref bibliographic top candidate ratio 0.50 — no plausible match)
  - References not verified automatically are resolved manually within 24 hours.

## Post-publication record

- **Status:** Clean
- **Summary:** No retraction or expression of concern found in Crossref (includes Retraction Watch).
- **Last checked:** 2026-11-25