#methodological rigourPrinted trion equation requires a correction
Equation (16) repeats one V-polarized transition. As printed, it gives decay rates TH and TH + 2TV rather than TH + TV for both excited states, so the stated photon-output formula does not follow without correcting the transition.
↳ Section IV, Eqs. (16)–(18)
#methodological rigourHamiltonian comparison uses inconsistent polarization bases
Appendix B assigns unequal decay rates in the exciton eigenbasis but counts output in the rotated cavity basis. Its normalization failure therefore does not establish that effective-Hamiltonian methods generally fail for asymmetric cavities.
↳ Appendix B, Eqs. (B1) and (B4); Section V
#methodological rigourNear-unity output omits full device losses
The maximum NH = 0.94 assumes ideal initialization and collection of every cavity photon. Excitation and collection trade-offs are discussed but not jointly calculated, and photon indistinguishability is not evaluated alongside that maximum.
↳ Section II; Section III.A, Fig. 3(b); Section V