# On-chip tunable quantum interference in a lithium niobate-on-insulator photonic integrated circuit

- **DOI:** [10.1088/2058-9565/ad4b98](https://doi.org/10.1088/2058-9565/ad4b98)
- **Rating:** Sound (3.2 out of 5)
- **Verdict:** Thermo-optic LNOI circuitry delivers tunable quantum interference and single-photon routing, but its novelty and stability framing exceeds the demonstrated advance.
- **Framework version:** v5.13
- **Pipeline version:** v0.4
- **Evaluation date:** 2026-11-25
- **Evaluation page:** https://www.nabu.science/paper/10.1088%2F2058-9565%2Fad4b98

## Key claims

1. We show Hong-Ou-Mandel interference with fully tunable visibilities reaching a maximum value of 97.4 ± 1.0%.
   - Support: Supported
   - Type: Primary finding
   - Basis: single-device interference measurements support tunability despite smoothing and thermal drift limiting peak-visibility precision
   - Location: Abstract; Section 4, Fig. 4(d)-(g); Appendix E
2. We demonstrate the effectiveness of our device for quantum applications by measuring single-photon routing with up to 34 dB extinction ratio.
   - Support: Supported
   - Type: Secondary
   - Basis: single-device characterization demonstrates the cross-port maximum without establishing equivalent extinction at both ports
   - Location: Abstract; Section 4, Fig. 4(b)
3. We use a thermo-optic phase shifter to achieve stable performance with a power consumption of Pπ = 44.4 mW and sub-microsecond switching times.
   - Support: Tentative
   - Type: Secondary
   - Basis: long-term stability was not benchmarked despite acknowledged thermal drift during multi-hour quantum measurements
   - Location: Abstract; Section 3, Fig. 3
4. We showed that the thermo-optically tuned MZI can reach extinction ratios above 31 dB symmetrically on both ports and reached optical response times as low as 0.7µs by employing an overdrive protocol.
   - Support: Supported
   - Type: Secondary
   - Basis: single-device measurements establish symmetric extinction at 1516 nm and overdriven heating rise time rather than full-cycle switching speed
   - Location: Section 5, Conclusion
5. The device uses TOPS to introduce phase shifts which feature a low Pπ = 44.4 mW achieved with CMOS compatible voltages below 5 V.
   - Support: Supported
   - Type: Secondary
   - Basis: phase-shift power and operating voltage are characterized on one device rather than replicated across devices
   - Location: Section 5, Conclusion

## Strengths

- **Quantum operation demonstrated in complementary experiments** Single-photon routing reaches 34.0 dB cross-port extinction, and two-input measurements demonstrate tunable HOM interference. Classical measurements provide a corresponding reference for the routing response.
  - Dimension: contribution
  - Location: Sections 3–4; Figures 3–4
- **Physical modeling checked against separate measurements** Directional-coupler simulations account for bend coupling and fabrication trenching and are compared with cascaded-coupler measurements. A separate resistive-sensor experiment characterizes lateral thermal crosstalk.
  - Dimension: methodological rigour
  - Location: Section 2; Appendix B, Figure B1(c); Appendix C, Figure C1
- **Measurement qualifications remain visible to readers** The text reports the asymmetric port extinction and the differing routing and HOM operating voltages. Appendix E supplies raw coincidence points and explicitly identifies low-visibility estimates as upper bounds.
  - Dimension: reporting
  - Location: Section 4; Appendix E, Figure E1

## Limitations

- **Platform novelty exceeds the thermo-optic advance** The abstract claims reconfigurable two-photon interference had not been achieved on LNOI, while Section 1 and Table 1 acknowledge an electro-optic LNOI predecessor. The demonstrated advance is the thermo-optic implementation rather than the broader platform capability.
  - Dimension: contribution
  - Location: Abstract; Section 1, reference [18]; Table 1; Section 5
- **Stable performance lacks a matching demonstration** The abstract asserts stable performance, but the routing and HOM experiments place the 50:50 operating point near 3.5 V and 4.75 V respectively. Section 4 attributes this difference to unmonitored thermal variation during multi-hour acquisition and acknowledges long-term stability issues.
  - Dimension: positioning
  - Location: Abstract; Section 4, thermal-drift discussion
- **Peak visibility precision remains incompletely established** HOM traces are smoothed before fitting without establishing how induced correlations enter the uncertainty. The 97.4 ± 1.0% on-chip maximum also remains unreconciled with the 94.0 ± 0.3% reference measurement, whose stated splitter-tolerance explanation is quantitatively insufficient under a simple imbalance calculation.
  - Dimension: methodological rigour
  - Location: Section 4; Appendices D–E

## Reliability checks

Caveats (4 of 4 checks).

- **Results check:** Noted
  - "The maximum visibility of 97.4 ± 1.0% was observed for U = 4.75 V" (Section 4, HOM results) vs "HOM interference with a visibility of 94.0 ± 0.3% is observed" (Appendix D). Assuming the stated splitter tolerance means R = 0.515 and T = 0.485 gives V = 2RT/(R² + T²) ≈ 99.82%, while the measured visibilities differ by 3.4 percentage points, approximately 3.3 combined standard errors. The effect on the result is unclear.
- **Reporting and transparency:** Noted. Figure E1 points to Figure 3(e) instead of the visibility panel in Figure 4(e). Conflict-of-interest and data-on-request declarations are present.
  - Conflict of interest: declared · Data availability: declared
- **Reference integrity:** Clean. 46 of 46 checkable references verified
  - 47 references in manuscript
  - 1 have no canonical index record — counted, but not index-checkable
  - 44 references confirmed by manual review
  - References not verified automatically are resolved manually within 24 hours.

## Post-publication record

- **Status:** Clean
- **Summary:** No retraction or expression of concern found in Crossref (includes Retraction Watch).
- **Last checked:** 2026-11-25
