# Novel multifunctional plasmonic fiber probe: Enabling plasmonic heating and SERS sensing for biomedical applications

- **DOI:** [10.1063/5.0303808](https://doi.org/10.1063/5.0303808)
- **Rating:** Sound (3.0 out of 5)
- **Verdict:** A gold-nanoisland fiber probe demonstrates visible-light heating and near-infrared Raman sensing, but independent operation in liquid remains experimentally unvalidated.
- **Framework version:** v5.13
- **Pipeline version:** v0.4
- **Evaluation date:** 2026-11-25
- **Evaluation page:** https://www.nabu.science/paper/10.1063%2F5.0303808

## Key claims

1. we demonstrate efficient, wavelength-dependent heating under visible light and strong SERS signal enhancement under near-infrared excitation, both supported by electromagnetic and thermal simulations.
   - Support: Supported
   - Type: Primary finding
   - Basis: separate heating and Raman measurements support dual functionality without establishing operational independence or quantifying enhancement
   - Location: Abstract
2. Increasing the initial film thickness from 5 nm to 10 nm results in a change of AuNIs morphology and higher optical extinction and greater photothermal efficiency (PE) due to enhanced plasmonic absorption.
   - Support: Tentative
   - Type: Secondary
   - Basis: two-device comparisons and conflicting absorption explanations limit the proposed morphology-to-heating mechanism
   - Location: Section 3, Conclusion
3. Numerical modeling further revealed that, in a liquid environment, temperature gradients of 5-8 °C can be achieved using 20 mW input power at 473 nm or 633 nm.
   - Support: Tentative
   - Type: Secondary
   - Basis: water heating is simulation-only with no experimental liquid validation and unquantified agreement against air measurements
   - Location: Conclusion; Section 2.2
4. Notably, SERS enhancement was detectable at power levels as low as 1 mW, demonstrating the high sensitivity of the platform even at low excitation powers.
   - Support: Tentative
   - Type: Secondary
   - Basis: single-concentration benzenethiol detection at low laser power does not identify analytical sensitivity
   - Location: Section 2.3
5. For PFP2, under 20 mW laser excitation, the temperature increases at the fiber tip are 7.66 °C at 473 nm (PE=0.38°C/mW), 7.2 °C at 633 nm (PE=0. 26°C/mW), and 1.66 °C at 785 nm (PE=0.08°C/mW).
   - Support: Tentative
   - Type: Secondary
   - Basis: unvalidated water simulations include a 633 nm efficiency requiring correction from 0.26 to 0.36 °C/mW
   - Location: Section 2.2, PFP2 water simulations

## Strengths

- **Distinct wavelengths support two probe functions** Visible-light heating and 785 nm benzenethiol Raman detection are demonstrated on the dewetted gold-nanoisland fiber architecture, extending its functional characterization beyond sensing alone.
  - Dimension: contribution
  - Location: Sections 2.2–2.3; Figures 3 and 6
- **Flat gold films anchor heating comparisons** Five- and ten-nanometer gold films provide direct comparators for wavelength-dependent nanoisland heating. The fabrication and thermal measurement procedures specify deposition, annealing and repeated power sweeps.
  - Dimension: methodological rigour
  - Location: Figure 3; Sections 4.1–4.2
- **Prior devices and modeling assumptions situated** The Introduction distinguishes earlier SERS and combined-function fibers, while the thermal discussion acknowledges periodic-model simplifications, camera averaging and reduced heating in water.
  - Dimension: positioning
  - Location: Introduction; Sections 2.1–2.2

## Limitations

- **SERS sensitivity lacks benchmarking and replication** A single 6 mM benzenethiol preparation supports detection, but no concentration series, enhancement factor or independent SERS probe count is reported. Detectability at 1 mW does not establish high analytical sensitivity.
  - Dimension: methodological rigour
  - Location: Section 2.3; Section 4.3; Figure 6
- **Liquid and tandem operation remain unvalidated** The 5–8 °C water-heating result comes entirely from simulations, with no quantitative model-to-experiment validation reported. Heating and sensing are not tested sequentially or simultaneously on the same sample.
  - Dimension: methodological rigour
  - Location: Sections 2.2–2.3; Figures 4–6
- **Reported water efficiencies require numerical correction** At 633 nm, the stated temperature rises and 20 mW input imply efficiencies of approximately 0.32 and 0.36 °C/mW, not 0.38 and 0.26. The correction materially changes the PFP2 coefficient, although the temperature-rise range survives.
  - Dimension: reporting
  - Location: Section 2.2, water-simulation results

## Reliability checks

Concerns (4 of 4 checks).

- **Results check:** Concern
  - "7.2 °C at 633 nm (PE=0. 26°C/mW)" (Section 2.2, PFP2 water simulations). Using the stated 20 mW input and the definition of PE, 7.2 °C / 20 mW = 0.36 °C/mW rather than 0.26 °C/mW. If corrected, the size of the result changes materially.
  - "at 633 nm results in a 6.38 °C temperature gradient (PE=0.38°C/mW)" (Section 2.2, PFP1 water simulations). Using the stated 20 mW input and the definition of PE, 6.38 °C / 20 mW = 0.319 °C/mW rather than 0.38 °C/mW, without changing the stated temperature-rise range. The result itself is unaffected.
  - "This explains why PFP1, with denser AuNI packing and smaller gaps, shows a stronger absorption peak compared to PFP2." (Section 2.1) vs "The higher PE of PFP2 compared to PFP1 aligns with its greater optical absorbance across all tested wavelengths." (Section 2.2). Section 2.1 assigns the stronger absorption peak to PFP1, whereas Section 2.2 explains PFP2's higher PE through greater absorbance across all tested wavelengths, without reconciling these statements. The effect on the result is unclear.
- **Reporting and transparency:** Clean. Conflict of interest is disclosed and ethics approval is not applicable to the reported bench study. The future repository statement is an availability assessability gap, not an established conduct concern.
  - Conflict of interest: declared · Data availability: not stated
- **Reference integrity:** Noted
  - 38 references in manuscript
  - 38 of 38 checkable references found in an index
  - the reference list may be incompletely parsed; counts are indicative
  - References not verified automatically are resolved manually within 24 hours.

## Post-publication record

- **Status:** Clean
- **Summary:** No retraction or expression of concern found in Crossref (includes Retraction Watch).
- **Last checked:** 2026-11-25