#methodological rigourModel equations do not validate the mechanism
Equation 8 has the wrong absorption-response sign at fixed reflectance, and Eqs. 9–10 use problematic spatial attenuation assumptions. Manual qualitative fitting and an unexplained absorption-coefficient change from 10^6 to 10^10 1/m further limit the claimed explanation.
↳ Figs. 3–4; Eqs. 8–10; Conclusion
#reportingSimulated emission collection is presented as coupling
The approximately 20% value comes from an FDTD dipole-emission collection simulation. It does not establish measured material–waveguide coupling or the guided-mode absorption fraction used in the device interpretation.
↳ Abstract; Fig. 5 and accompanying discussion
#methodological rigourIntegrated saturation lacks controls and replication details
No bare-waveguide power sweep excludes baseline nonlinearity or alternative responses across the measurement range. Changed grating alignment complicates normalization, while independent device counts and the basis of the 0.15(9) µW uncertainty are unspecified.
↳ Fig. 6 caption and accompanying results