#methodological rigourShort temporal records limit independent verification
The displayed 1 µs record spans about 100 cycles, too little to distinguish locking from slow phase drift at the relevant tens-of-kHz detunings. The phase-noise improvement is also shown graphically without a quantified reduction or uncertainty.
↳ Results, Temporal Traces and Phase Noise; Fig. 3a-d
#methodological rigourQualitative simulations rely on mismatched assumptions
The model neglects secondary displacement under a large main-to-secondary amplitude assumption, yet its simulated oscillators have similar amplitudes. Coupling is selected to match the observed synchronization range, limiting the simulations as an independent quantitative test.
↳ Supplement S3, Spontaneous synchronization; Fig. 2f-i and Fig. 8
#methodological rigourSingle pair leaves broader performance untested
No second device pair or repeat-sweep uncertainty is reported, and a separate control for reference-tone leakage is not shown. The discussion does not fully trace how mechanical frequency dispersion and thermal tuning constrain extension to larger networks.
↳ Results, Tested Device and Experimental Setup and Spontaneous Synchronization; Figs. 1–2; Discussion