# CMOS-compatible high-speed endless automatic polarization controller

- **DOI:** [10.1063/5.0198227](https://doi.org/10.1063/5.0198227)
- **Rating:** Sound (3.3 out of 5)
- **Verdict:** Silicon polarization tracking reaches 20 krad/s, substantially advancing the reported silicon benchmark, but polarization-dependent loss limits confidence in tracking fidelity.
- **Framework version:** v5.13
- **Pipeline version:** v0.4
- **Evaluation date:** 2026-11-25
- **Evaluation page:** https://www.nabu.science/paper/10.1063%2F5.0198227

## Key claims

1. attain an unprecedented polarization control speed of up to 20 krad/s, with this rate being solely limited by the capabilities of our characterization equipment
   - Support: Tentative
   - Type: Primary finding
   - Basis: two tested speed points do not identify the device limit or establish equipment as its sole constraint
   - Location: Abstract; Section IV.D; Fig. 6
2. under a 50 kHz square-wave signal, the TPS’s fall response time (from 100% to 10%) is 4.7 μs and the rise response time (from 0% to 90%) is 3.2 μs
   - Support: Tentative
   - Type: Secondary
   - Basis: the measured rise and fall differ despite the central presentation of a single unqualified response time
   - Location: Section IV.B, Fig. 4(c)
3. At 20 krad/s, the RIE remains below 0.21 for 99% of the time, with a maximum of 0.45.
   - Support: Supported
   - Type: Secondary
   - Basis: one-hour sampled feedback measurements support these statistics without excluding brief excursions between samples
   - Location: Section IV.D
4. our silicon-based APC not only leads among its silicon counterparts but also surpasses some lithium niobate-based APCs
   - Support: Supported
   - Type: Secondary
   - Basis: the listed tracking-speed comparisons support the statement without establishing equivalent cross-study test conditions
   - Location: Section V; Table I
5. Based on our measurements, we determined that the loaded power is ∼25.3 mW, and the corresponding Vπ is around 10.5 V.
   - Support: Supported
   - Type: Secondary
   - Basis: static MZI spectral-shift measurements directly characterize the reported phase-shifter power and voltage
   - Location: Section IV.A, Fig. 3(e)

## Strengths

- **Substantial advance over listed silicon benchmarks** The demonstrated 20 krad/s tracking point is approximately 16 times the 1.256 krad/s silicon comparator in Table I. The comparison establishes a meaningful reported speed advance, although test conditions are not shown to be identical.
  - Dimension: contribution
  - Location: Section IV.D; Table I
- **Separate component and closed-loop performance measurements** Passive spectral characterization, direct thermal step-response measurements, and one-hour tracking-error distributions examine distinct parts of the system. The dynamic test reports a 3.2 μs rise time and a 4.7 μs fall time.
  - Dimension: methodological rigour
  - Location: Sections IV.A–D; Figs. 3–6
- **Discussion connects device limitations to performance** Section V explains how grating-coupler polarization-dependent loss perturbs feedback intensity and control iterations. It also identifies drive-voltage and thermal-power trade-offs and proposes corresponding device changes.
  - Dimension: positioning
  - Location: Section V

## Limitations

- **Operating wavelength leaves feedback calibration unresolved** Tracking is tested at 1550 nm, where the input coupler has 12.57 dB polarization-dependent loss. Without demonstrated total-power normalization or equivalent calibration, feedback intensity does not cleanly isolate polarization-tracking error.
  - Dimension: methodological rigour
  - Location: Section IV.A, Fig. 3(c); Section IV.D, Fig. 6(a)
- **Equipment-only speed limit is not established** Successful tracking at 20 krad/s and loss of lock at 70 krad/s leave the intervening device limit unmeasured. The Abstract's equipment-only explanation implies performance headroom that these tests do not establish.
  - Dimension: reporting
  - Location: Abstract; Section IV.D; Fig. 6
- **Continuous lock exceeds the measurement resolution** The 10 kHz logging interval is 100 μs, so brief unlocks between samples cannot be excluded. Missing RIE and loop-timing specifications, together with the unpresented 10-hour record, further limit assessment of uninterrupted operation.
  - Dimension: methodological rigour
  - Location: Sections IV.C–D; Fig. 6 caption

## Reliability checks

Caveats (4 of 4 checks).

- **Results check:** Noted. One reported value does not reconcile, but the key claims do not rest on it.
  - Minor reporting notes (1):
    - "Among them, neff is the effective refractive rate of the coupling area, L is the length of the coupling area" (Section IV.A) vs "We have introduced an additional 20 μm geometric difference in the upper arm of the MZI structure." (Figure 3(b) caption). Compare the coupling-area definition of L accompanying Eq. (4) with the explicitly stated MZI arm-length difference used in the test structure. The result itself is unaffected.
- **Reporting and transparency:** Noted. Ten-hour stable operation is asserted without accompanying duration-specific results, whereas the presented statistical characterization covers one hour. Conflicts are disclosed and supporting data are offered upon reasonable request.
  - Conflict of interest: declared · Data availability: declared
- **Reference integrity:** Clean. 41 of 41 checkable references verified
  - 41 references in manuscript
  - 9 references confirmed by manual review
  - References not verified automatically are resolved manually within 24 hours.

## Post-publication record

- **Status:** Clean
- **Summary:** No retraction or expression of concern found in Crossref (includes Retraction Watch).
- **Last checked:** 2026-11-25