# Graphene absorber on an SOI chip for active and passive mode locking of lasers.

- **DOI:** [10.1038/s41598-025-93051-z](https://doi.org/10.1038/s41598-025-93051-z)
- **Rating:** Sound (3.1 out of 5)
- **Verdict:** A wafer-scale graphene-on-silicon device delivers passive pulses and GHz-driven fiber-cavity operation, but incomplete mechanism validation limits the mode-locking interpretation.
- **Framework version:** v5.13
- **Pipeline version:** v0.4
- **Evaluation date:** 2026-11-25
- **Evaluation page:** https://www.nabu.science/paper/10.1038%2Fs41598-025-93051-z

## Key claims

1. We demonstrate both passive and active mode-locking of fiber lasers using a graphene-based absorber integrated on a silicon photonics platform manufactured using a wafer-scale CMOS process.
   - Support: Tentative
   - Type: Primary finding
   - Basis: incomplete active temporal verification and an absent passive reference-cavity control limit the combined demonstration
   - Location: Abstract
2. Passive mode-locking is achieved at a fundamental repetition rate of 27.9 MHz, producing pulses as short as 1.7 ps.
   - Support: Supported
   - Type: Secondary
   - Basis: direct pulse-train and autocorrelation measurements support the output despite the missing control isolating graphene's role
   - Location: Introduction final paragraph; Fig. 4
3. Active mode-locking is achieved at repetition rates up to 10 GHz, fulfilling the requirements of high-speed ADC systems.
   - Support: Tentative
   - Type: Secondary
   - Basis: spectral-only active characterization lacks temporal pulse verification and an ADC-specific performance comparison
   - Location: Introduction final paragraph; Figs. 9–10

## Strengths

- **Wafer-scale fabrication with electrically gated operation** The graphene-on-silicon absorber combines wafer-scale CMOS-compatible fabrication with electrical control and operation in passive and GHz-driven fiber cavities. The introduction delineates this extension against earlier integrated passive devices and lower-frequency active graphene systems.
  - Dimension: contribution
  - Location: Introduction; Graphene Absorber Design; Figs. 4 and 9–10
- **Passive pulse output receives complementary measurements** The passive operating point is characterized by an oscilloscope pulse train, a 51 dB RF signal-to-noise ratio and autocorrelation yielding a 1.7 ps deconvoluted pulse width at 27.9 MHz.
  - Dimension: methodological rigour
  - Location: Passively Mode-Locked Laser Cavity; Fig. 4
- **Physical bandwidth limitations linked to performance** The discussion connects grating-coupler bandwidth and EDFA gain shape to achievable pulse performance. The transmission measurements also identify competition between graphene saturation and silicon two-photon absorption.
  - Dimension: positioning
  - Location: Saturable Absorption; Discussion and Conclusion

## Limitations

- **Passive mechanism lacks a discriminating control** The polarization-sensitive cavity has no reported no-graphene reference-waveguide test to isolate graphene absorption from polarization-based mode-locking. Passive operation at −0.7 V also lies within the range showing little to no saturation in the independent transmission measurements.
  - Dimension: methodological rigour
  - Location: Saturable Absorption; Figs. 2–4
- **Active locking claims exceed temporal validation** The active results rely on RF, phase-noise and optical spectra without a measured pulse width or direct temporal trace. This leaves modulation versus locked pulse generation insufficiently distinguished and makes the stated fulfillment of high-speed ADC requirements premature.
  - Dimension: reporting
  - Location: Abstract; Introduction, final paragraph; Active Mode-Locking; Figs. 9–10
- **Repeatability remains unquantified across operating sweeps** No run-to-run or device-to-device variability is reported for the parameter trends. The disclosed 0.5 ps pulse-width difference under identical nominal conditions is comparable to the pulse-width variation reported across the pump and length sweep.
  - Dimension: methodological rigour
  - Location: Passively Mode-Locked Laser Cavity; Figs. 5–6

## Reliability checks

No concerns (4 of 4 checks).

- **Results check:** Clean. The reported numbers and statistics are consistent with the stated results.
- **Reporting and transparency:** Clean. Competing interests are disclosed and data are available on reasonable request. No applicable ethics-reporting concern is established.
  - Conflict of interest: declared · Data availability: declared
- **Reference integrity:** Clean
  - 51 references in manuscript
  - 51 of 51 checkable references found in an index
  - References not verified automatically are resolved manually within 24 hours.

## Post-publication record

- **Status:** Clean
- **Summary:** No retraction or expression of concern found in Crossref (includes Retraction Watch).
- **Last checked:** 2026-11-25
